[1]徐佳欢,张文雯,吕宇航,等.第3代双源CT低剂量Turbo Flash成像图像质量与诊断效能的临床研究[J].国际放射医学核医学杂志,2018,(6):500-506.[doi:10.3760/cma.j.issn.1673-4114.2018.06.005]
 Xu Jiahuan,Zhang Wenwen,Lyu Yuhang,et al.Study of image quality and diagnostic accuracy of low-dose coronary angiography using third-generation dual-source CT with free breathing and heart rate[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(6):500-506.[doi:10.3760/cma.j.issn.1673-4114.2018.06.005]
点击复制

第3代双源CT低剂量Turbo Flash成像图像质量与诊断效能的临床研究(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
期数:
2018年第6期
页码:
500-506
栏目:
临床研究
出版日期:
2018-12-31

文章信息/Info

Title:
Study of image quality and diagnostic accuracy of low-dose coronary angiography using third-generation dual-source CT with free breathing and heart rate
作者:
徐佳欢13 张文雯1 吕宇航1 籍庆余1 陈国强1 韩瑞娟2 苏宇航2 孙凯1
1. 014040, 包头医学院中心临床医学院, 包头市中心医院影像科;
2. 014040, 包头医学院中心临床医学院, 包头市中心医院心内科;
3. 014030, 包头市肿瘤医院影像科
Author(s):
Xu Jiahuan13 Zhang Wenwen1 Lyu Yuhang1 Ji Qingyu1 Chen Guoqiang1 Han Ruijuan2 Su Yuhang2 Sun Kai1
1. Department of Image, Baotou Central Hospital, Central Clinical Medical College, Baotou Medical College, Baotou 014040, China;
2. Department of Cardiology, Baotou Central Hospital, Central Clinical Medical College, Baotou Medical College, Baotou 014040, China;
3. Department of Image, Baotou Cancer Hospital, Baotou 014030, China
关键词:
体层摄影术X线计算机冠状动脉疾病辐射剂量第3代双源CT
Keywords:
Tomography X-ray computedCoronary artery diseaseRadiation dosageThe third generation dual-source CT
DOI:
10.3760/cma.j.issn.1673-4114.2018.06.005
摘要:
目的 探讨第3代双源CT大螺距前瞻性心电门控扫描模式(Turbo Flash)冠状动脉CT成像(CCTA)评价冠状动脉狭窄的准确性、图像质量及有效辐射剂量。方法 前瞻性收集2016年4月至2017年4月接受第3代双源CCTA检查的患者1003例,其中有70例患者在CCTA检查后30 d内行冠状动脉造影(CAG)。对冠状动脉各节段图像质量进行评分,计算有效辐射剂量。以CAG结果为“金标准”,计算CCTA显示冠状动脉病变的灵敏度、特异度、阳性预测值和阴性预测值;CCTA与CAG评价冠状动脉狭窄分级的一致性采用Kappa值并进行U检验。结果 (1)图像质量:右冠状动脉不可诊断血管节段为0,左冠状动脉主干及前降支不可诊断血管节段为0,左冠状动脉回旋支不可诊断血管节段为0.04%(3/835)。(2)准确性评价:基于节段水平分析,Force CT诊断冠状动脉狭窄的灵敏度为97.0%(289/298)、特异度为98.3%(706/718)、阳性预测值为96.0%(289/301)、阴性预测值为98.7%(706/715);基于血管分析,灵敏度为97.5%(159/163)、特异度为85.1%(40/47)、阳性预测值为95.8%(159/166)、阴性预测值为90.9%(40/44);基于患者分析,灵敏度、特异度、阳性预测值、阴性预测值均为100%。CCTA与CAG显示的冠状动脉狭窄部位高度一致(U=2.4,P=0.008)。(3)辐射剂量:有效辐射剂量为(1.17±0.29)mSv。结论 第3代双源CT Turbo Flash模式可以在自然呼吸、无心率干预下进行冠状动脉成像,扫描成功率高,图像质量佳,评价冠状动脉狭窄的准确性高,有效辐射剂量低。
Abstract:
Objective To prospectively investigate the diagnostic accuracy, image quality, and radiation doses of electrocardiogram (ECG)-triggered high-pitch acquisition (turbo flash) coronary computed tomography(CT) angiography(CCTA) using third-generation dual-source CT compared with coronary angiography(CAG) for the diagnosis of significant coronary stenoses. Methods Prospectively collected 1003 patients who received the third-generation dual-source CCTA examination from April 2016 to April 2017. Among them, 70 patients underwent coronary angiography(CAG) 30 days after CCTA examination to score the image quality of each segment of coronary artery and calculate the effective radiation dose. The sensitivity, specificity, positive predictive value and negative predictive value of CCTA for coronary artery lesions were calculated using CAG results as the gold standard. The consistency of CCTA and CAG in grading coronary artery stenosis was evaluated by Kappa value and U test. Results (1) Image quality:no non-diagnostic image quality was observed in the right coronary artery nor left anterior descending artery. The rate of coronary segments with non-diagnostic image quality reached 0.04% in the left circumflex artery. (2) Diagnostic accuracy:the sensitivity, specificity, and positive and negative predictive values totaled 97.0%(289/298), 98.3%(706/718), 96.0%(289/301), 98.7%(706/715) for segment assessment and 97.5%(159/163), 85.1% (40/47), 95.8%(159/166), 90.9%(40/44) for vessel assessment, and all the values are 100% for patients assessment. CCTA was highly consistent with the site of coronary artery stenosis shown by CAG(U=2.4, P<0.05). ⑶ Radiation doses:the effective radiation dose was(1.17±0.29) mSv on average. Conclusions CCTA using the prospectively ECG-triggered high-pitch mode (turbo flash) of the third-generation dual-source CT system is associated with high diagnostic accuracy for the assessment of coronary artery stenoses at low doses.

参考文献/References:

[1] 陈伟伟, 高润霖, 刘力生, 等. 《中国心血管病报告》摘要[J]. 中国循环杂志, 2016, 31(6):521-528. DOI:10.3969/j.issn.1000-3614. 2017.06.001. Chen WW, Gao RL, Liu LS, et al. Summary of China Cardiovascular Disease Report[J]. Chin Circ J, 2016, 31(6):521-528. DOI:10.3969/j.issn.1000-3614.2017.06.001.
[2] Zhang LJ, Wang Y, Schoepf UJ, et al. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting:comparison with invasive coronary angiography[J]. Eur Radiol, 2016, 26(3):797-806. DOI:10.1007/s00330-015-3868-z.
[3] Sun K, Han RJ, Ma LJ, et al. Prospectively electrocardiogram-gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with high heart rates:comparison with retrospective electrocardiogram-gated spiral acquisition mode[J]. Korean J Radiol, 2012, 13(6):684-693. DOI:10.3348/kjr.2012.13. 6.684.
[4] 孙凯, 韩瑞娟, 赵瑞平, 等. 不同心率患者采用大螺距双源CT冠状动脉成像的图像质量及影响因素分析[J]. 中华放射学杂志, 2012, 46(9):773-778. DOI:10.3760/cma.j.issn.1005-1201.2012. 09.001. Sun K, Han RJ, Zhao RP, et al. The image quality and influencing factors of high-pitch dual-source CT coronary angiography in patients with different heart rates[J]. Chin J Radiol, 2012, 46(9):773-778. DOI:10.3760/cma.j.issn.1005-1201.2012.09.001.
[5] Sun K, Liu GR, Li YC, et al. Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography:Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique[J]. Chin Med Sci J, 2013, 27(4):225-231.
[6] Wu FZ, Wu MT. 2014 SCCT guidelines for the interpretation and reporting of coronary CT angiography:a report of the Society of Cardiovascular Computed Tomography Guidelines Committee[J]. J Cardiovasc Comput Tomogr, 2015, 9(2):e3. DOI:10.1016/j.jcct.2015.01.003.
[7] Leipsic J, Abbara S, Achenbach S, et al. SCCT guidelines for the interpretation and reporting of coronary CT angiography:a report of the Society of Cardiovascular Computed Tomography Guidelines Committee[J]. J Cardiovasc Comput Tomogr, 2014, 8(5):342-358. DOI:10.1016/j.jcct.2014.07.003.
[8] Trattner S, Halliburton S, Thompson CM, et al. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography[J]. JACC Cardiovasc Imaging, 2018, 11(1):64-74. DOI:10.1016/j.jcmg.2017.06.006.
[9] 孙凯, 韩瑞娟, 马利军, 等. 大螺距双源CT前瞻性心电门控扫描评价冠状动脉狭窄的临床研究[J]. 中华放射学杂志, 2012, 46(1):49-53. DOI:10.3760/cma.j.issn.1005-1201.2012.01.012. Su K, Han RJ, Ma LJ, et al. The study of diagnostic accuracy of prospectively electrocardiogram-triggered high-pitch spiral acquisition using Flash dual-source CT for the assessment of coronary stenoses[J]. Chin J Radiol, 2012, 46(1):49-53. DOI:10.3760/cma.j.issn.1005-1201.2012.01.012.
[10] Zheng M, Wei M, Wen D, et al. Transluminal attenuation gradient in coronary computed tomography angiography for determining stenosis severity of calcified coronary artery:a primary study with dual-source CT[J]. Eur Radiol, 2015, 25(5):1219-1228. DOI:10.1007/s00330-014-3519-9.
[11] Sato S, Horii Y, Yoshimura N, et al. Coronary computed tomography angiography using 128-slice dual-source computed tomography in patients with severe calcification[J]. Jpn J Radiol, 2017, 35(8):432-439. DOI:10.1007/s11604-017-0650-y.
[12] Mangold S, Wichmann JL, Schoepf UJ, et al. Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection:Clinical application in a non-obese and obese patient population[J]. Eur Radiol, 2017, 27(6):2298-2308. DOI:10.1007/s00330-016-4601-2.
[13] Apfaltrer G, Szolar DH, Wurzinger E, et al. Impact on Image Quality and Radiation Dose of Third-Generation Dual-Source Computed Tomography of the Coronary Arteries[J]. Am J Cardiol, 2017, 119(8):1156-1161. DOI:10.1016/j.amjcard.2016.12.028.
[14] Linsen PV, Coenen A, Lubbers MM, et al. Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System:Improvements in Image Quality and Radiation Dose[J]. J Clin Imaging Sci, 2016, 6:44. DOI:10.4103/2156-7514.192840.
[15] Gordic S, Husarik DB, Desbiolles L, et al. High-pitch coronary CT angiography with third generation dual-source CT:limits of heart rate[J]. Int J Cardiovasc Imaging, 2014, 30(6):1173-1179. DOI:10.1007/s10554-014-0445-5.
[16] Meyer M, Haubenreisser H, Schoepf UJ, et al. Closing in on the K edge:coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second-versus a third-generation dual-source CT system[J]. Radiology, 2014, 273(2):373-382. DOI:10.1148/radiol.14140244.
[17] Hell MM, Bittner D, Schuhbaeck A, et al. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage:feasibility, image quality, radiation dose, and effect of iterative reconstruction[J]. J Cardiovasc Comput Tomogr, 2014, 8(6):418-425. DOI:10.1016/j.jcct.2014. 09. 003.
[18] Hausleiter J, Meyer TS, Martuscelli E, et al. Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography:the multicenter, multivendor, randomized PROTECTION-Ⅲ study[J]. JACC Cardiovasc Imaging, 2012, 5(5):484-493. DOI:10.1016/j.jcmg.2011.12.017.

相似文献/References:

[1]周翠屏,廖俊杰,何国华,等.原发性肠系膜巨大淋巴结增生症的MSCT表现与病理对照分析[J].国际放射医学核医学杂志,2016,40(3):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
 Zhou Cuiping,Liao Junjie,He Guohua,et al.Primary mesenteric Castleman disease:MSCT findings with histopathologic correlation[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
[2]尤阳,轩昂,张杰,等.淋巴瘤患者大脑静息葡萄糖代谢改变[J].国际放射医学核医学杂志,2016,40(4):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
 You Yang,Xuan Ang,Zhang Jie,et al.Changes in resting-state brain glucose metabolism in patients with lymphoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
[3]王朋,崔邦平,代文莉,等.18F-FDG PET/CT在前列腺癌中的应用进展[J].国际放射医学核医学杂志,2016,40(4):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]
 Wang Peng,Cui Bangping,Dai Wenli,et al.Progress in the application of 18F-FDG PET/CT in prostate cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]
[4]李菲,黄俊星,张俊.18F-FDG PET/CT在食管癌中的临床应用[J].国际放射医学核医学杂志,2016,40(4):282.[doi:10.3760/cma.j.issn.1673-4114.2016.04.009]
 Li Fei,Huang Junxing,Zhang Jun.The clinical application of 18F-FDG PET/CT in esophageal cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):282.[doi:10.3760/cma.j.issn.1673-4114.2016.04.009]
[5]刘淑蓉,孙凯.低辐射剂量冠状动脉成像的研究进展[J].国际放射医学核医学杂志,2016,40(4):293.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
 Liu Shurong,Sun Kai.The advances of low radiation dose coronary computed tomography angiography imaging[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):293.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
[6]郑雪,孙凯.双源双能量CT心肌灌注成像的研究进展[J].国际放射医学核医学杂志,2016,40(4):301.[doi:10.3760/cma.j.issn.1673-4114.2016.04.013]
 Zheng Xue,Sun Kai.Progress of dual-energy myocardial perfusion imaging by dual-source computed tomography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):301.[doi:10.3760/cma.j.issn.1673-4114.2016.04.013]
[7]徐佳欢,孙凯.第二代双源CT大螺距模式低辐射剂量血管成像进展[J].国际放射医学核医学杂志,2016,40(5):389.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
 Xu Jiahuan,Sun Kai.Application of high-pitch and low-dose mode using dual-source CT by computed tomography angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):389.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
[8]蔡培坤,梁辉晖,董琴,等.640层螺旋CT冠脉成像对心肌桥-壁冠状动脉的形态学量化评价及粥样硬化相关性分析[J].国际放射医学核医学杂志,2016,40(6):442.[doi:10.3760/cma.j.issn.1673-4114.2016.06.008]
 Cai Peikun,Liang Huihui,Dong Qin,et al.Quantitative evaluation of morphological characteristics and their correlation with atherosclerosis of the myocardial bridge-mural coronary artery by 640 multi-detector spiral CT[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):442.[doi:10.3760/cma.j.issn.1673-4114.2016.06.008]
[9]徐勐,张越,傅菲,等.MSCT上肢静脉直接成像技术的应用[J].国际放射医学核医学杂志,2015,39(6):462.[doi:10.3760/cma.j.issn.1673-4114.2015.06.006]
 Xu Meng,Zhang Yue,Fu Fei,et al.The application of MSCT in upper limb vein direct imaging[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(6):462.[doi:10.3760/cma.j.issn.1673-4114.2015.06.006]
[10]安淑娴,宋少莉,黄钢.放射性核素标记的凋亡显像剂的研究进展[J].国际放射医学核医学杂志,2015,39(6):470.[doi:10.3760/cma.j.issn.1673-4114.2015.06.008]
 An Shuxian,Song Shaoli,Huang Gang.Recent advances in apoptosis imaging using radionuclide-labeled tracers[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(6):470.[doi:10.3760/cma.j.issn.1673-4114.2015.06.008]
[11]周玉祥,蓝博文,黄春榆,等.64排螺旋CT冠状动脉血管成像诊断冠状动脉-肺动脉瘘的应用价值[J].国际放射医学核医学杂志,2016,40(1):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
 Zhou Yuxiang,Lan Bowen,Huang Chunyu,et al.Clinical value of coronary artery-pulmonary artery fistula revealed by 64-slice spiral CT coronary angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
[12]陈超坤,刘亮,傅飞先,等.囊性胸腺瘤和囊性畸胎瘤的影像学特征及鉴别诊断[J].国际放射医学核医学杂志,2016,40(1):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
 Chen Chaokun,Liu Liang,Fu Feixian,et al.Imaging features and differential diagnosis of cystic thymoma and cystic teratoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
[13]岳进,苏丽萍.全身MRI与PET/CT在淋巴瘤骨髓浸润诊断及预后中的作用[J].国际放射医学核医学杂志,2016,40(1):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
 Yue Jin,Su Lipin.Function of whole-body MRI and PET/CT in the diagnosis and prognosis of lymphoma with bone marrow infiltration[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
[14]张莹莹,王振光,孔艳.PET/CT显像在肺间质纤维化中的应用进展[J].国际放射医学核医学杂志,2016,40(1):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
 Zhang Yingying,Wang Zhenguang,Kong Yan.Application advancement on PET/CT in pulmonary interstitial fibrosis[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
[15]麦卫平,张永林.能谱CT成像在肺癌诊断中的应用研究进展[J].国际放射医学核医学杂志,2016,40(1):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
 Mai Weiping,Zhang Yonglin.Research progress of spectral imaging in the diagnosis of lung cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
[16]史文杰,孟召伟,谭建.基于Deauville标准探讨18F-FDG PET/CT在霍奇金淋巴瘤复发诊断中的应用价值[J].国际放射医学核医学杂志,2016,40(2):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
 Shi Wenjie,Meng Zhaowei,Tan Jian.Value of 18F-FDG PET/CT on diagnosis of Hodgkin lymphoma recurrence using Deauville criterion[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
[17]张巧娜,刘汉东.上颌窦上皮-肌上皮癌的CT表现一例[J].国际放射医学核医学杂志,2016,40(3):237.[doi:10.3760/cma.j.issn.1673-4114.2016.03.015]
[18]张巍,杨珂.18f正电子放射性药物生产及使用中医务人员的受照剂量研究[J].国际放射医学核医学杂志,2015,39(5):420.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 016]
 zhang wei,yang ke..the research of radiation dose of 18f-fdg to pet/ct related personnel[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(6):420.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 016]
[19]曹登敏,林美福,陈文新,等.继发性骨淋巴瘤的18F-FDG PET/CT影像学表现[J].国际放射医学核医学杂志,2016,40(6):403.[doi:10.3760/cma.j.issn.1673-4114.2016.06.001]
 Cao Dengmin,Lin Meifu,Chen Wenxin,et al.Analysis on 18F-FDG PET/CT imaging characteristics in secondary bone lymphoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):403.[doi:10.3760/cma.j.issn.1673-4114.2016.06.001]
[20]李生栩,唐明灯,林端瑜,等.18F-FDG PET/CT在胸段食管鳞癌淋巴结转移中的诊断价值[J].国际放射医学核医学杂志,2016,40(6):408.[doi:10.3760/cma.j.issn.1673-4114.2016.06.002]
 Li Shengxu,Tang Mingdeng,Lin Duanyu,et al.Value of 18F-FDG PET/CT in detecting metastatic lymph nodes of thoracic esophageal squamous cell carcinoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(6):408.[doi:10.3760/cma.j.issn.1673-4114.2016.06.002]

备注/Memo

备注/Memo:
收稿日期:2018-02-24。
基金项目:国家自然科学基金(81560286);内蒙古自治区卫生和计划生育委员会项目(201302124)
通讯作者:孙凯,Email:Henrysk@163.com
更新日期/Last Update: 2018-12-31