[1]徐佳欢,孙凯.第二代双源CT大螺距模式低辐射剂量血管成像进展[J].国际放射医学核医学杂志,2016,40(5):389-393.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
 Xu Jiahuan,Sun Kai.Application of high-pitch and low-dose mode using dual-source CT by computed tomography angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):389-393.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
点击复制

第二代双源CT大螺距模式低辐射剂量血管成像进展(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
40
期数:
2016年第5期
页码:
389-393
栏目:
综述
出版日期:
2016-09-25

文章信息/Info

Title:
Application of high-pitch and low-dose mode using dual-source CT by computed tomography angiography
作者:
徐佳欢12 孙凯2
1. 014040, 包头医学院;
2. 014040, 包头市中心医院影像科
Author(s):
Xu Jiahuan12 Sun Kai2
1. Baotou Medical College, Baotou 014040, China;
2. Department of Image, Baotou Central Hospital, Baotou 014040, China(Xu JH, Sun K)
关键词:
体层摄影术螺旋计算机辐射剂量CT血管成像
Keywords:
Tomographyspiral computedRadiation dosageComputed tomography angiography
DOI:
10.3760/cma.j.issn.1673-4114.2016.04.011
摘要:
双源CT应用临床以来,在CT血管造影方面越来越显示出其独特优势,其较高的时间和空间分辨率及较快的扫描速度使获得高质量的图像成为可能。双源CT大螺距扫描模式在血管成像方面具有图像质量好、有效射线剂量低、扫描时间快等优点。笔者就第二代双源CT大螺距模式在血管成像方面的进展及临床应用价值进行综述。
Abstract:
Given the unique advantages of dual-source computed tomography(DSCT), such as high temporary and spatial resolutions and fast scanning speed,its application in angiography has made possible for high-quality images to be obtained. In high-pitch scanning mode, DSCT can obtain high-quality angiography images with low effective radiation dose at a short scan time. This paper reviewed the progress and clinical applications of high-pitch mode DSCT in computed tomography angiography.

参考文献/References:

[1] 中华放射学杂志心脏冠状动脉多排CT临床应用协作组.心脏冠状动脉多排CT临床应用专家共识[J].中华放射学杂志, 2011, 45(1):9-17.DOI:10.3760/cma.j.issn.1005-1201.2011.01.003.Chinese Journal of Radiology Heart Coronary Artery Multi-Detector Row CT Clinical Applications of Collaboration.Expert consensus document of Chinese Journal of Radiology on clinical applications of cardiac and coronary artery imaging by multi-detector row CT[J].Chin J Radiol, 2011, 45(1):9-17.
[2] Westwood ME, Raatz HD, Misso K, et al.Systematic review of the accuracy of dual-source cardiac CT for detection of arterial stenosis in difficult to image patient groups[J].Radiology, 2013, 267(2):387-395.DOI:10.1148/radiol.13121136.
[3] Achenbach S, Manolopoulos M, Schuhbaeck AA, et al.Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries[J].J Cardiovasc Comput Tomogr, 2012, 6(2):91-98.DOI:10.1016/j.jcct.2011.11.006.
[4] Husmann L, Leschka S, Desbiolles L, et al.Coronary artery motion and cardiac phases:dependency on heart rate-implications for CT image reconstruction[J].Radiology, 2007, 245(2):567-576.DOI:10.1148/radiol.2451061791.
[5] 孙凯, 韩瑞娟, 李坤成.心脏电-机械耦联与双源CT冠状动脉成像最佳成像时间窗[J].中华临床医师杂志:电子版, 2013, 7(23):10875-10879.DOI:10.3877/cma.j.issn.1674-0785.2013.23.111.Sun K, Han RJ, Li KC.Cardiac electrical mechanical coupling and the optimal electrocardiographic pulsing Windows for Dual-source CT coronary angiography[J].Chin J Clinicians(Electronic Edition), 2013, 7(23):10875-10879.
[6] Goetti R, Feuchtner G, Stolzmann P, et al.High-pitch dual-source CT coronary angiography:systolic data acquisition at high heart rates[J].Eur Radiol, 2010, 20(11):2565-2571.DOI:10.1007/s00330-010-1838-z.
[7] Sun K, Han RJ, Cui LF, et al.Feasibility and diagnostic accuracy for assessment of coronary artery stenosis of prospectively electrocardiogram-gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with relatively higher heart rates:in comparison with catheter coronary angiography[J].Chin Med Sci, 2013, 27(4):213-219.
[8] 孙凯, 韩瑞娟, 赵瑞平, 等.不同心率患者采用大螺距双源CT冠状动脉成像的图像质量及影响因素分析[J].中华放射学杂志, 2012, 46(9):773-778.DOI:10.3760/cma.j.issn.1005-1201.2012.09.001.Sun K, Han RJ, Zhao RP, et al.The image quality and influencing factors of high-pitch dual-source CT coronary angiography in patients with different heart rates[J].Chin J Radiol, 2012, 46(9):773-778.
[9] 孔令燕, 刘冬, 王怡宁, 等.双源CT冠状动脉成像评价冠状动脉支架通畅性[J].中国医学科学院学报, 2010, 32(6):601-606.DOI:10.3881/j.issn.1000-503X.2010.06.002.Kong LY, Liu D, Wang YN, et al.Assessment of coronary stent lumen visibility and patency by Dual-source computed tomographic Angiography[J].Acta Acad Med Sin, 2010, 32(6):601-606.
[10] 羊镇宇, 王强, 郭素峡, 等.双源CT在冠状动脉支架内再狭窄诊断中的价值[J].中华心血管病杂志, 2011, 39(1):49-52.DOI:10.3760/cma.j.issn.0253-3758.2011.01.010.Yang ZY, Wang Q, Guo SX, et al.Value of detecting in-stent restenosis by dual source coronary computed tomography coronary angiography[J].Chin J Cardiol, 2011, 39(1):49-52.
[11] Wang LF, Tao LW, Huang MX, et al.Clinical evaluation of coronary in-stent restenosis using dual-source computed tomography[J].Echocardiography, 2015, 32(11):1681-1687.DOI:10.1111/echo.12932.
[12] Lee YW, Yang CC, Mok GS, et al.Prospectively versus retrospectively ECG-gated 256-slice CT angiography to assess coronary artery bypass grafts-comparison of image quality and radiation dose[J/OL].PLoS One, 2012, 7(11):e49212[2016-04-10].http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0049212.DOI:10.1371/journal.pone.0049212.
[13] Heye T, Kauczor HU, Szabo G, et al.Computed tomography angiography of coronary artery bypass grafts:robustness in emergency and clinical routine settings[J].Acta Radiol, 2014, 55(2):161-170.DOI:10.1177/0284185113494977.
[14] Goetti R, Leschka S, Baumueller S, et al.Low dose High-Pitch spiral acquisition 128-Slice Dual-Source computed tomography for the evaluation of coronary artery bypass graft patency[J].Invest Radiol, 2010, 45(6):324-330.DOI:10.1097/RLI.0b013e3181dfa47e.
[15] Einstein AJ, Wolff SD, Manheimer ED, et al.Comparison of image quality and radiation does of coronary computed tomographic angiography between conventional helical scanning and a strategy incorporating sequential scanning[J].Am J Cardiol, 2009, 104(10):1343-1350.DOI:10.1016/j.amjcard.2009.07.003.
[16] Zheng MW, Wu YJ, Wei MQ, et al.Low-Concentration contrast medium for 128-Slice Dual-Source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-Pitch spiral acquisition[J].Acad Radiol, 2015, 22(2):195-202.DOI:10.1016/j.acra.2014.07.025.
[17] Marwan M, Mettin C, Pflederer T, et al.Very low-dose coronary artery Calcium scanning with high-pitch spiral acquisition mode:comparison between 120-kV and 100-kV tube voltage protocols[J].J Cardiovasc Comput Tomogr, 2013, 7(1):32-38.DOI:10.1016/j.jcct.2012.11.004.
[18] Zhang LJ, Qi L, De Cecco CN, et al.High-Pitch coronary CT angiography at 70 kVp with low contrast medium volume comparison of 80 and 100 kVp High-Pitch protocols[J].Medicine(Baltimore), 2014, 93(22):18.DOI:10.1097/MD.0000000000000092.
[19] Fuchs TA, Stehli J, Bull S, et al.Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination[J].Eur Heart J, 2014, 35(17):1131-1136.DOI:10.1093/eurheartj/ehu053.
[20] Schuhbaeck A, Achenbach S, Layritz C, et al.Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose<0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction[J].Eur Radiol, 2013, 23(3):597-606.
[21] Koplay M, Kizilca O, Cimen D, et al.Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities:Radiation dose and diagnostic efficacy in a pediatric population[J/OL].Diagn Interv Imaging, 2016, pii:S2211-5684(16)30078-X[2016-04-10].http://www.sciencedirect.com/science/article/pii/S221156841630078X.DOI:10.1016/j.diii.2016.03.014.
[22] Koplay M, Celik M, AvciA, et al.Comparison between prospectively electrocar diogram-Gated high-pitch mode and retrospectively electrocardiogram-gated mode for dual-source CT coronary angiography[J/OL].Pol J Radiol, 2015, 80:561-568[2016-04-10].http:www.ncbi.nlm.gov/pmc/articles/PMC4699622.DOI:10.12659/PJR.895232.eCollection 2015.
[23] Matsubara K, Sakuda K, Nunome H, et al.128-slice dual-source CT coronary angiography with prospectively electrocardiography-triggered high-pitch spiral mode:radiation dose, image quality, and diagnostic acceptability[J].Acta Radiol, 2016, 57(1):25-32.DOI:10.1177/0284185114562467.
[24] Apfaltrer P, Hanna EL, Schoepf U, et al.Radiation dose and image quality at High-Pitch CT angiography of the aorta:intraindividual and interindividual comparisons with conventional CT angiography[J].AJR Am J Roentgenol, 2012, 199(6):1402-1409.DOI:10.2214/AJR.12.8652.
[25] Bolen MA, Popovic ZB, Tandon N, et al.Image quality, contrast enhancement, and radiation dose of ECG-triggered high-pitch CT versus non-ECG-triggered standard-pitch CT of the thoracoabdominal aorta[J].AJR Am J Roentgenol, 2012, 198(4):931-938.
[26] 戴颖钰, 马新星, 陈铟铟, 等.四种CT扫描模式对肺动脉成像图像质量和辐射剂量的影响[J].中国医学影像学杂志, 2015, 23(1):4-7, 9.DOI:10.3969/j.issn.1005-5185.2015.01.002.Dai YY, Ma XX, Chen YY, et al.Effect of four CT scan modes on image quality and radiation dose of pulmonary angiography[J].Chin J Med Imaging, 2015, 23(1):4-7, 9.
[27] Lu GM, Luo S, Meinel FG, et al.High-pitch computed tomography pulmonary angiography with iterative Reconstruction at 80 kVp and 20 mL contrast agent volume[J].Eur Radiol, 2014, 24(12):3260-3268.DOI:10.1007/s00330-014-3365-9.
[28] Bauer RW, Schell B, Beeres M, et al.High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients[J].J Thorac Imaging, 2012, 27(6):376-381.DOI:10.1097/RTI.0b013e318250067e.
[29] Wang ZW, Chen Y, Wang Y, et al.Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries[J/OL].PLoS One, 2014, 9(3):e90268[2016-04-10].http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0090268.DOI:10.1371/journal.pone.0090268.
[30] Sun K, Li K, Han R, et al.Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries[J].Eur J Radiol, 2015, 84(3):398-406.DOI:10.1016/j.ejrad.2014.11.009.

相似文献/References:

[1]周玉祥,蓝博文,黄春榆,等.64排螺旋CT冠状动脉血管成像诊断冠状动脉-肺动脉瘘的应用价值[J].国际放射医学核医学杂志,2016,40(1):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
 Zhou Yuxiang,Lan Bowen,Huang Chunyu,et al.Clinical value of coronary artery-pulmonary artery fistula revealed by 64-slice spiral CT coronary angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
[2]陈超坤,刘亮,傅飞先,等.囊性胸腺瘤和囊性畸胎瘤的影像学特征及鉴别诊断[J].国际放射医学核医学杂志,2016,40(1):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
 Chen Chaokun,Liu Liang,Fu Feixian,et al.Imaging features and differential diagnosis of cystic thymoma and cystic teratoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
[3]岳进,苏丽萍.全身MRI与PET/CT在淋巴瘤骨髓浸润诊断及预后中的作用[J].国际放射医学核医学杂志,2016,40(1):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
 Yue Jin,Su Lipin.Function of whole-body MRI and PET/CT in the diagnosis and prognosis of lymphoma with bone marrow infiltration[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
[4]张莹莹,王振光,孔艳.PET/CT显像在肺间质纤维化中的应用进展[J].国际放射医学核医学杂志,2016,40(1):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
 Zhang Yingying,Wang Zhenguang,Kong Yan.Application advancement on PET/CT in pulmonary interstitial fibrosis[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
[5]麦卫平,张永林.能谱CT成像在肺癌诊断中的应用研究进展[J].国际放射医学核医学杂志,2016,40(1):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
 Mai Weiping,Zhang Yonglin.Research progress of spectral imaging in the diagnosis of lung cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
[6]史文杰,孟召伟,谭建.基于Deauville标准探讨18F-FDG PET/CT在霍奇金淋巴瘤复发诊断中的应用价值[J].国际放射医学核医学杂志,2016,40(2):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
 Shi Wenjie,Meng Zhaowei,Tan Jian.Value of 18F-FDG PET/CT on diagnosis of Hodgkin lymphoma recurrence using Deauville criterion[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
[7]张巧娜,刘汉东.上颌窦上皮-肌上皮癌的CT表现一例[J].国际放射医学核医学杂志,2016,40(3):237.[doi:10.3760/cma.j.issn.1673-4114.2016.03.015]
[8]尤阳,轩昂,张杰,等.淋巴瘤患者大脑静息葡萄糖代谢改变[J].国际放射医学核医学杂志,2016,40(4):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
 You Yang,Xuan Ang,Zhang Jie,et al.Changes in resting-state brain glucose metabolism in patients with lymphoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
[9]王朋,崔邦平,代文莉,等.18F-FDG PET/CT在前列腺癌中的应用进展[J].国际放射医学核医学杂志,2016,40(4):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]
 Wang Peng,Cui Bangping,Dai Wenli,et al.Progress in the application of 18F-FDG PET/CT in prostate cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]
[10]李菲,黄俊星,张俊.18F-FDG PET/CT在食管癌中的临床应用[J].国际放射医学核医学杂志,2016,40(4):282.[doi:10.3760/cma.j.issn.1673-4114.2016.04.009]
 Li Fei,Huang Junxing,Zhang Jun.The clinical application of 18F-FDG PET/CT in esophageal cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):282.[doi:10.3760/cma.j.issn.1673-4114.2016.04.009]
[11]周翠屏,廖俊杰,何国华,等.原发性肠系膜巨大淋巴结增生症的MSCT表现与病理对照分析[J].国际放射医学核医学杂志,2016,40(3):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
 Zhou Cuiping,Liao Junjie,He Guohua,et al.Primary mesenteric Castleman disease:MSCT findings with histopathologic correlation[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
[12]蔡培坤,梁辉晖,董琴,等.640层螺旋CT冠脉成像对心肌桥-壁冠状动脉的形态学量化评价及粥样硬化相关性分析[J].国际放射医学核医学杂志,2016,40(6):442.[doi:10.3760/cma.j.issn.1673-4114.2016.06.008]
 Cai Peikun,Liang Huihui,Dong Qin,et al.Quantitative evaluation of morphological characteristics and their correlation with atherosclerosis of the myocardial bridge-mural coronary artery by 640 multi-detector spiral CT[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):442.[doi:10.3760/cma.j.issn.1673-4114.2016.06.008]
[13]徐勐,张越,傅菲,等.MSCT上肢静脉直接成像技术的应用[J].国际放射医学核医学杂志,2015,39(6):462.[doi:10.3760/cma.j.issn.1673-4114.2015.06.006]
 Xu Meng,Zhang Yue,Fu Fei,et al.The application of MSCT in upper limb vein direct imaging[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):462.[doi:10.3760/cma.j.issn.1673-4114.2015.06.006]
[14]陈彩龙,林美福,周硕,等.颞骨MSCT及多种后处理技术在婴幼儿人工耳蜗植入术中的临床应用[J].国际放射医学核医学杂志,2015,39(2):136.[doi:10.3760/cma.j.issn.1673-4114.2015.02.007]
 Chen Cailong,Lin Meifu,Zhou Shuo,et al.Clinical application of multislice spiral CT for temporal bone and multiple post-processing reconstruction techniques for infant cochlear implantation[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):136.[doi:10.3760/cma.j.issn.1673-4114.2015.02.007]
[15]陈亮,田春梅,王培源,等.MSCTU对儿童泌尿系集合系统及输尿管畸形的诊断价值[J].国际放射医学核医学杂志,2014,38(2):84.[doi:10.3760/cma.j.issn.1673-4114.2014.02.004]
 Chen Liang,Tian Chunmei,Wang Peiyuan,et al.The diagnosis value of MSCTU in child congenital anomalies of urinary system[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(5):84.[doi:10.3760/cma.j.issn.1673-4114.2014.02.004]
[16]蒿崑,孙珊珊,王凯.64排螺旋CT在小膀胱肿瘤诊断中的应用价值[J].国际放射医学核医学杂志,2014,38(4):242.[doi:10.3760/cma.j.issn.1673-4114.2014.04.009]
 Hao Kun,Sun Shanshan,Wang Kai.Application value of 64 multi-detector helical CT for diagnosis of small bladder tumor[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(5):242.[doi:10.3760/cma.j.issn.1673-4114.2014.04.009]
[17]侯朝华,宋立杰,潘砚章.多层螺旋CT在诊断茎突综合征中的应用价值[J].国际放射医学核医学杂志,2012,36(1):59.[doi:10.3760/cma.j.issn.1673-4114.2012.01.015]
 HOU Zhao-hua,SONG Li-jie,PAN Yan-zhang.Multiple-detector spiral CT in diagnosis of the application value of styloid process syndrome[J].International Journal of Radiation Medicine and Nuclear Medicine,2012,36(5):59.[doi:10.3760/cma.j.issn.1673-4114.2012.01.015]
[18]刘良卿,郑建刚,杨克宇,等.急性氯气中毒患者胸部影像学表现分析[J].国际放射医学核医学杂志,2012,36(2):124.[doi:10.3760/cma.j.issn.1673-4114.2012.02.017]
 LIU Liang-qing,ZHENG Jian-gang,YANG Ke-yu,et al.Analysis of chest image performance in patients with acute chlorine poisoning[J].International Journal of Radiation Medicine and Nuclear Medicine,2012,36(5):124.[doi:10.3760/cma.j.issn.1673-4114.2012.02.017]
[19]孟庆玉.影像学在典型及非典型急性阑尾炎诊断中的临床价值[J].国际放射医学核医学杂志,2013,37(6):349.[doi:10.3760/cma.j.issn.1673-4114.2013.06.006]
 MENG Qing-yu.Clinical value of imaging in the diagnosis of typical and atypical acute appendicitis[J].International Journal of Radiation Medicine and Nuclear Medicine,2013,37(5):349.[doi:10.3760/cma.j.issn.1673-4114.2013.06.006]
[20]梁萍,方华盛.螺旋CT最小密度投影曲面重建法胆道成像对胆道梗阻性疾病的诊断价值[J].国际放射医学核医学杂志,2010,34(5):308.[doi:10.3760/cma.j.issn.1673-4114.2010.05.016]
 LIA NG Ping,FA NG Hua-she ng.The value of technique combine minimum intensity projection with curved planar reformation of spiral CT in diagnosing biliary obstruction[J].International Journal of Radiation Medicine and Nuclear Medicine,2010,34(5):308.[doi:10.3760/cma.j.issn.1673-4114.2010.05.016]

备注/Memo

备注/Memo:
收稿日期:2016-04-11
基金项目:国家自然科学基金(81560286);内蒙古自治区卫生和计划生育委员会项目(201302124)
通讯作者:孙凯,Email:Henrysk@163.com
更新日期/Last Update: 1900-01-01