摘要:
尽管CT检查仅占所有检查的2%,而对于公众诊断性成像的接收剂量,CT却占20%左右。具有10mSy有效剂量的成人腹部检查会增加致癌风险1/2000。儿童对于放射线影响的灵敏度是中年人的10倍多,女孩比男孩更敏感。剂量增加的原因有:CT应用的偏差、使用方便的结果、多层CT的危机、未意识到"非耦合效应"。医护人员要进行很好的培训,要意识到不断涌现的资料及实践中潜在的变化,根据进展修正方案。像进行传统X射线摄影一样,"合理使用低剂量(as low as reasonably achievable,ALARA)"
Abstract:
Despite comprising only 2% of all examinations,CT contributed around 20% of the collective dose to the population from diagnostic imaging.An abdominal examination in an adult with an effective dose of 10mSv has been estimated to increase the lifetime risk of fatal cancer by 1 in 2000.Children are 10 times more sensitive to the effects of radiation than middleaged adults.Girls are more sensitive than boys.Variations in CT practice,ease of using,urgency in multislice CT,unawaring of the "uncoupling effect" in CT may be contributing to increasing in radiation dose.We must train.An awareness of emerging and the implied changes in practice,with revision of protocols to take account of advances.The "as low as reasonably achievable (ALARA)" principle applies just as much to CT as it does to conventional radiography.

参考文献/References:

[1] Golding S J, Shrimpton PC. Radiation dose in CT: are we meeting the challenge?[J]. Br J Radiol, 2002, 75: 1-4.
[2] Slovis TL. CT and computed radiography: the pictures are great, but is the radiation dose greater than required?[J].Am J Roentgenol, 2002, 179: 39-41.

相似文献/References:

[1]邓大平,卢峰,孙洪强,等.颅脑肿瘤放射治疗时射野外器官吸收剂量体模法测量与分析[J].国际放射医学核医学杂志,2016,40(4):272.[doi:10.3760/cma.j.issn.1673-4114.2016.04.007]
 Deng Daping,Lu Feng,Sun Hongqiang,et al.Test and analysis of out-of-field organ dose in intracranial tumor radiotherapy using phantom[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):272.[doi:10.3760/cma.j.issn.1673-4114.2016.04.007]
[2]马永忠,王宏芳,冯泽臣,等.回旋加速器工作场所辐射水平的调查与分析[J].国际放射医学核医学杂志,2015,39(5):407.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 013]
 ma yongzhong,wang hongfang,feng zechen,et al.investigation and analysis of radiation dose levels in a cyclotron room[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(4):407.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 013]
[3]张欣,孙志娟,赵永成.医用X射线工作者回顾性剂量估算进展[J].国际放射医学核医学杂志,2016,40(5):379.[doi:10.3760/cma.j.issn.1673-4114.2016.05.009]
 Zhang Xin,Sun Zhijuan,Zhao Yongcheng.Advances in retrospective dose estimation for medical X-ray workers[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):379.[doi:10.3760/cma.j.issn.1673-4114.2016.05.009]
[4]徐佳欢,孙凯.第二代双源CT大螺距模式低辐射剂量血管成像进展[J].国际放射医学核医学杂志,2016,40(5):389.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
 Xu Jiahuan,Sun Kai.Application of high-pitch and low-dose mode using dual-source CT by computed tomography angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):389.[doi:10.3760/cma.j.issn.1673-4114.2016.04.011]
[5]郑玉明,程霞,郑棒.自制90Sr保持架在皮肤病敷贴治疗中的辐射防护作用[J].国际放射医学核医学杂志,2014,38(1):19.[doi:10.3760/cma.j.issn 1673-4114.2014.01.005]
 Zheng Yuming,Cheng Xia,Zheng Bang.Effects of serf-made 90Sr applicator retainer on radiation protection in treatment of skin disease[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(4):19.[doi:10.3760/cma.j.issn 1673-4114.2014.01.005]
[6]成钊汀,谭建.分化型甲状腺癌术后患者131I治疗的辐射剂量与防护[J].国际放射医学核医学杂志,2014,38(2):110.[doi:10.3760/cma.j.issn.1673-4114.2014.02.010]
 Cheng Zhaoting,Tan Jian.Radiation dose and protection of differentiated thyroid carcinoma postoperative patients with 131I treatment[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(4):110.[doi:10.3760/cma.j.issn.1673-4114.2014.02.010]
[7]王亮,张文艺,焦玲.CR-39固体探测器蚀刻后径迹分析和影响因素分析[J].国际放射医学核医学杂志,2014,38(2):130.[doi:10.3760/cma.j.issn.1673-4114.2014.02.013]
 Wang Liang,Zhang Wenyi,Jiao Ling.Track analysis and influencing factors analysis on CR-39 solid state detector after etching[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(4):130.[doi:10.3760/cma.j.issn.1673-4114.2014.02.013]
[8]武萍,李思进,张艳兰,等.基于30mA管电流低剂量呼吸门控PET/CT扫描条件的建立讨论[J].国际放射医学核医学杂志,2013,37(5):257.[doi:10.3760/cma.j.issn.1673-4114.2013.05.001]
 WU Ping,LI Si-jin,ZHANG Yan-lan,et al.Low-dose respiratory-gated PET/CT: based on 30 mA tube current[J].International Journal of Radiation Medicine and Nuclear Medicine,2013,37(4):257.[doi:10.3760/cma.j.issn.1673-4114.2013.05.001]
[9]王忠周,刘素兰,王新怡,等.影响数字乳腺X线摄影辐射剂量因素研究[J].国际放射医学核医学杂志,2012,36(2):113.[doi:10.3760/cma.j.issn.1673-4114.2012.02.014]
 WANG Zhong-zhou,LIU Su-lan,WANG Xin-yi,et al.Study on factors of influence to radiation dose of digital mammography[J].International Journal of Radiation Medicine and Nuclear Medicine,2012,36(4):113.[doi:10.3760/cma.j.issn.1673-4114.2012.02.014]
[10]张良安,张文艺,焦玲,等.《β射线所致皮肤剂量估算规范》释疑[J].国际放射医学核医学杂志,2012,36(4):238.[doi:10.3760/cma.j.issn.1673-4114.2012.04.011]
 ZHANG Liang-an,ZHA NG Wen-yi,JIAO Ling,et al.Explanation of Specifications of Skin Dose Estimagon from β Ray Exposure[J].International Journal of Radiation Medicine and Nuclear Medicine,2012,36(4):238.[doi:10.3760/cma.j.issn.1673-4114.2012.04.011]

备注/Memo

备注/Memo:
收稿日期:2002-12-23
作者简介:王骏(1967-),男,主管技师,主要从事医学影像技术学研究。
更新日期/Last Update: 1900-01-01