[1]马永忠,王宏芳,冯泽臣,等.回旋加速器工作场所辐射水平的调查与分析[J].国际放射医学核医学杂志,2015,39(5):407-411.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 013]
 ma yongzhong,wang hongfang,feng zechen,et al.investigation and analysis of radiation dose levels in a cyclotron room[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):407-411.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 013]
点击复制

回旋加速器工作场所辐射水平的调查与分析(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
39
期数:
2015年第5期
页码:
407-411
栏目:
论著
出版日期:
2015-09-15

文章信息/Info

Title:
investigation and analysis of radiation dose levels in a cyclotron room
作者:
马永忠王宏芳冯泽臣朱维杰孙亚茹娄云万玲孟庆华田青香
100013,北京市疾病预防控制中心放射卫生防护所
Author(s):
ma yongzhong wang hongfangfeng zechen zhu weijie sun yaru lou yun wan ling meng qinghua tian qingxiang.
institute of radiohygiene protection, beijing center for disease control and prevention, beijing 100013, china
关键词:
回旋加速器回旋加速器室辐射剂量辐射防护
Keywords:
cyclotron cyclotron room radiation dose radiation protection
DOI:
10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 013
摘要:
目的 调查回旋加速器工作场所辐射剂量水平及其分布状况,以期更好地指导现场人员的防护并为放射性药物生产场所的屏蔽设计提供技术依据。方法 以某医院安装的1台hm-20s型回旋加速器及其放射性药物生产场所为研究对象,使用lif(mg,cu,p)热释光剂量计、cr39中子剂量计、nh-1b中子剂量当量率仪和451b剂量巡测仪测量加速器室内中子和γ射线辐射剂量率,并对室外关注点的辐射水平进行验证。结果 在质子能量20 mev、束流100 μa条件下,回旋加速器自屏蔽体南侧表面中子最高剂量率为北侧表面的63倍、γ射线最高剂量率为北侧的6.0倍;机房南墙内表面中子和γ射线剂量率分别为北墙内表面的11倍和5.3倍;机房东墙内表面中子和γ射线剂量率平均值分别为21 μsv/h和45 μsv/h,西墙内表面中子和γ射线剂量率平均值分别为34 μsv/h和69 μsv/h。结论 回旋加速器室内辐射水平及其分布状况与束流方向和靶位置等因素密切相关,其实测值可用于指导场所的屏蔽设计和人员防护。
Abstract:
objective levels and distribution of radiation dose in a cyclotron room were investigated to guide protection of personnel against radiation onsite and provide technical basis for the shielding design of workplaces with radioactive drugs. methods a cyclotron hm-20s and the room in a hospital where it was installed were investigated. several lif(mg,cu,and p) thermoluminescence dosimeters,cr39 neutron dosimeters,a neutron dose equivalent rate meter nh-1b,and a dose survey meter 451 b were used to measure the neutron and gamma radiation dose rates in the cyclotron room. radiation dose levels outside the room were also validated. results when irradiation conditions were 20 mev of proton energy and 100 μa of beam current, the maximum neutron dose rate from the southern surface of the self-shielding body of the equipment was 63 times higher than that from northern surface of the self-shielding body. additionally,the maximum gamma-ray dose rate of the southern surface was 6.0 times higher than that of the northern surface. neutron and gamma-ray dose rates measured on the inner surface of the southern wall were 11 and 5.3 times higher than those measured on the inner surface of the northern wall,respectively. in addition,mean values of neutron and gamma-ray radiation dose rates from the inner surface of the eastern wall were 21 and 45 μsv/h,correspondingly,whereas those from the western side were 34 and 69 μsv/h,respectively. conclusion levels and distribution of radiation dose in a cyclotron room are closely related to several factors,such as beam direction and target position. radiation dose values measured onsite can be used to facilitate the shielding design of workplaces and provide radiation safety for personnel.

参考文献/References:

[1]dirk r, bertrand k, annelaure d, et al. synthesis of fluorine-18-labelled tspo ligands for imaging neuroinflammation with positron emission tomography[j/ol]. j fluorine chemistry, 2012, 134:107-114[2015-05-20]. http://www. sciencedirect. com/science/article/pii/s0022113911000868.
[2]任庆余, 杨星, 张延华, 等. 医用回旋加速器辐射剂量检测与评价[j]. 医疗卫生装备, 2014, 35(4):84-85.
[3]马永忠, 万玲, 娄云, 等. 回旋加速器放射性药物生产场所的防护设计与分析[j]. 首都公共卫生, 2013, 7(1):7-13.
[4]tan eh, goh sw. exploring new frontiers in molecular imaging:emergence of 68ga pet/ct[j]. world j radiol, 2010, 2(2):55-67.
[5]包宝亮, 何玉林, 李剑波. 自屏蔽回旋加速器辐射剂量测定[j]. 中国医疗设备, 2014, 29(1):122-123.
[6]iaea. applying radiation safety standards in nuclear medicine. iaea safety reports series no. 40. vienna:iaea, 2005.
[7]庞健, 何小中, 荆晓兵, 等. 正电子发射成像回旋加速器屏蔽材料防护性能[j]. 强激光与粒子束, 2013, 25(11):2981-2985.

相似文献/References:

[1]王劲,程亮,唐明灯,等.(N-[18F]氟甲基)胆碱的合成与质量控制[J].国际放射医学核医学杂志,2014,38(3):171.[doi:10.3760/cma.j.issn.1673-4114.2014.03.008]
 Wang Jin,Cheng Liang,Tang Mingdeng,et al.Synthesis and quality control of 18F-fluoromethyl choline[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(5):171.[doi:10.3760/cma.j.issn.1673-4114.2014.03.008]
[2]鄢敏,秦志星,程鹏亮,等.住友CLC模块在线优化合成13N-NH3·H2O的研究[J].国际放射医学核医学杂志,2014,38(6):360.[doi:10.3760/cma.j.issn.1673-4114.2014.06.003]
 Yan Min,Qin Zhi-xing,Cheng Peng-liang,et al.Online optimized synthesis of 13N-NH3·H2O by Sumitomo CLC module[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(5):360.[doi:10.3760/cma.j.issn.1673-4114.2014.06.003]
[3]王明芳.医用回旋加速器及正电子核素生产[J].国际放射医学核医学杂志,2002,26(5):231.
 WANG Ming-fang.Medical cyclotron and positron emitting nuclide[J].International Journal of Radiation Medicine and Nuclear Medicine,2002,26(5):231.

备注/Memo