[1]任越,张慧芳,胡波,等.电离辐射诱导小鼠骨电子顺磁共振信号检测的影响因素[J].国际放射医学核医学杂志,2015,39(5):371-374.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 004]
 ren yue,zhang huifang,hu bo,et al.influencing factors of detection on ionizing radiation-induced electron paramagnetic resonance signal in bones[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):371-374.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 004]
点击复制

电离辐射诱导小鼠骨电子顺磁共振信号检测的影响因素(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
39
期数:
2015年第5期
页码:
371-374
栏目:
论著
出版日期:
2015-09-15

文章信息/Info

Title:
influencing factors of detection on ionizing radiation-induced electron paramagnetic resonance signal in bones
作者:
任越张慧芳胡波王婧洁王宏利原雅艺张睿凤李幼忱
030006 太原,中国辐射防护研究院放射医学与环境医学研究所
Author(s):
ren yue zhang huifang hu bo wang jingjie wang hongli yuan yayi zhang ruifeng li youchen.
department of radiological medicine and environmental medicine, china institute for radiation protection, taiyuan 030006, china
关键词:
电离辐射电子顺磁共振小鼠
Keywords:
ionizing radiation bone electron paramagnetic resonance mice
DOI:
10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 004
摘要:
目的 研究影响小鼠骨辐射诱导电子顺磁共振(epr)信号检测的因素。方法 将小鼠股骨去除软组织和骨髓,干燥,制成股骨段,经60co γ射线照射,照射剂量率为5 gy/min,照射剂量为10 gy和50 gy。检测不同干燥程度、检测方向、微波功率和叠加次数等条件下骨epr的信号强度。结果 降低骨样品含水量、设置合适的微波功率、增加叠加次数均可以增加样品信号强度,且不同检测方向下同一份样品的信号强度有一定差异。结论 适当的样品预处理和检测参数设定可以提高骨epr检测的灵敏度,样品多方向检测并取平均值可减弱骨样品不均一产生的影响。
Abstract:
objective to study the influencing factors of detection on ionizing radiation-induced electron paramagnetic resonance(epr) signal in mice bone. methods soft tissue and bone marrow samples of mice femur were collected, and femur sections were dried. the femur sections were irradiated at 10 and 50 gy by 60co sources with irradiation dose rate of 5 gy/min. bone epr signal intensity was detected under different degrees of drying,detection direction,and microwave power,as well as various scan times. results the water content of the bone sample was reduced,and microwave power was set to an appropriate value. results showed that increasing scan times increased the signal intensity. additionally,different detection directions of the same sample resulted in differences in signal intensity. conclusion appropriate sample preparation and detection parameters can improve bone epr detection sensitivity. multidirectional detection of samples and averaging of the results may reduce the effects of inhomogeneity on bone samples.

参考文献/References:

[1]romanyukha aa, regulla df. aspects of retrospective esr dosimetry(invited paper)[j]. appl radiat isot, 1996, 47(11-12):1293-1297.
[2]shengli n, pascal d, hajo z. approaches to attribution of detrimental health effects to occupational ionizing radiation exposure and their application in compensation programmes for cancer[m]. geneva:ilo, 2010:66-67.
[3]caracelli i, terrile mc, mascarenhas s. electron spin resonance dosimetric properties of bone[j]. health phys, 1986, 50(2):259-263.
[4]吴可, 孙存普, 汤立达, 等. 60co γ射线照后骨组织esr信号特性及与照射剂量的关系[j]. 中华放射医学与防护杂志, 1993, 15(4):229-231.
[5]陈英, 周平坤, 吴可, 等. 放射损伤生物剂量估算技术的研究现状[j]. 辐射防护, 2008, 6:385-391.
[6]范亚光. 牙釉质esr回顾性剂量技术与剂量重建[j]. 国外医学·放射医学核医学分册, 2002, 26(2):90-92.
[7]刘青杰, 杨英杰, 陈金娣, 等. 60coγ射线急慢性照射对小鼠骨、牙和毛发esr信号的影响[j]. 辐射研究与辐射工艺学报, 2003, 21(3):198-201.
[8]赵永富, 哈益明, 刘婷, 等. 电子自旋共振波谱法检测含骨类食品的初步研究[j]. 辐射研究与辐射工艺学报, 2007, 25(5):279-282.
[9]赵保路. 电子自旋共振技术在生物和医学中的应用[m]. 合肥:中国科学技术大学出版社, 2009:13-14.
[10]ciesielski b, krefft k, penkowski m, et al. effects of water treatment and sample granularity on radiation sensitivity and stability of epr signals in x-ray irradiated bone samples[j]. radiat prot dosimetry, 2014, 159(1-4):141-148.
[11]wieser a, haskell e, kenner g, et al. epr dosimetry of bone gains accuracy by isolation of calcified tissue[j]. appl radiat isot, 1994, 45(4):525-526.

相似文献/References:

[1]郝新忠,武志芳,武萍,等.SAPHO综合征18F-FDG PET/CT显像和临床分析[J].国际放射医学核医学杂志,2015,39(6):447.[doi:10.3760/cma.j.issn.1673-4114.2015.06.003]
 Hao Xinzhong,Wu Zhifang,Wu Ping,et al.18F-FDG PET/CT imaging and clinical features of SAPHO syndrome[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):447.[doi:10.3760/cma.j.issn.1673-4114.2015.06.003]
[2]张胤,陈跃.18F-氟化钠PET/CT诊断肿瘤骨转移应用进展[J].国际放射医学核医学杂志,2015,39(1):96.[doi:10.3760/cma.j.issn.1673-4114.2015.01.020]
 Zhang Yin,Chen Yue.Application progress of 18F-NaF PET/CT in the diagnosis of neoplasm metastases[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(5):96.[doi:10.3760/cma.j.issn.1673-4114.2015.01.020]
[3]王平,关华顺,吕玉民.外周血核基因表达评价辐射生物剂量方法研究进展[J].国际放射医学核医学杂志,2014,38(6):416.[doi:10.3760/cma.j.issn.1673-4114.2014.06.016]
 Wang Ping,Guan Hua-shun,Lyu Yu-min.Advances of nuclear gene expression signatures in peripheral blood for irradiation biodose estimation[J].International Journal of Radiation Medicine and Nuclear Medicine,2014,38(5):416.[doi:10.3760/cma.j.issn.1673-4114.2014.06.016]
[4]徐畅,王彦,杜利清,等.shRNA干扰沉默Net1基因对电离辐射损伤反应的影响[J].国际放射医学核医学杂志,2013,37(3):135.[doi:10.3760/cma.j.issn.1673-4114.2013.03.002]
 XU Chang,WANG Yan,DU Li-qing,et al.The effects of short hairpin RNA-mediated silencing Net1 on ionizing radiation-induced damage responses[J].International Journal of Radiation Medicine and Nuclear Medicine,2013,37(5):135.[doi:10.3760/cma.j.issn.1673-4114.2013.03.002]
[5]刘忠超,张文艺,焦玲.辐射引起的电子自旋共振信号在回顾剂量学中的应用[J].国际放射医学核医学杂志,2013,37(5):322.[doi:10.3760/cma.j.issn.1673-4114.2013.05.016]
 LIU Zhong-chao,ZHANG Wen-yi,JIAO Ling.The application of radiation-induced free radicals signals in retrospective dosimetry[J].International Journal of Radiation Medicine and Nuclear Medicine,2013,37(5):322.[doi:10.3760/cma.j.issn.1673-4114.2013.05.016]
[6]白剑强,夏群,胡永成.放射性核素骨显像在脊柱转移瘤诊断中的价值[J].国际放射医学核医学杂志,2011,35(1):28.[doi:10.3760/cma.j.issn.1673-4114.2011.01.008]
 BAI Jian-qiang,XIA Qun,HU Yong-cheng.Evaluate the diagnostic value of radionuclide bone imaging of metastatic spine tumors[J].International Journal of Radiation Medicine and Nuclear Medicine,2011,35(5):28.[doi:10.3760/cma.j.issn.1673-4114.2011.01.008]
[7]徐海青,段俊,吴边.全身骨显像诊断前列腺癌骨转移与PSA水平及病理分级的相关性研究[J].国际放射医学核医学杂志,2011,35(1):34.[doi:10.3760/cma.j.issn.1673-4114.2011.01.010]
 XU Hai-qing,DUAN Jun,WU Bian.Study of relationship between the bone imaging, level of PSA and pathology grade in diagnosis of prostate carcinoma bone metastasis[J].International Journal of Radiation Medicine and Nuclear Medicine,2011,35(5):34.[doi:10.3760/cma.j.issn.1673-4114.2011.01.010]
[8]陶欣慰,黄钢.18F-FDGPET与99Tcm-MDP骨显像在诊断肿瘤骨转移中的比较[J].国际放射医学核医学杂志,2010,34(6):352.[doi:10.3760/cma.j.issn.1673-4114,2010.06.008]
 TAO Xin-wei,HUANG Gang.Comparasion of 18F-FDG PET and 99Tcm-MDP bone imaging in diagnosis of bone metastasis[J].International Journal of Radiation Medicine and Nuclear Medicine,2010,34(5):352.[doi:10.3760/cma.j.issn.1673-4114,2010.06.008]
[9]陈凤,涂彧.电离辐射诱导旁效应的研究现状[J].国际放射医学核医学杂志,2009,33(6):364.[doi:10.3760/cma.j.issn.1673-4114.2009.06.015]
 CHEN Feng,TU Yu.Bystander effect induced by ionizing radiation and its application[J].International Journal of Radiation Medicine and Nuclear Medicine,2009,33(5):364.[doi:10.3760/cma.j.issn.1673-4114.2009.06.015]
[10]肖瑶,韩玲.电离辐射诱导旁效应的研究现状[J].国际放射医学核医学杂志,2007,31(5):303.
 XIAO Yao,HAN Ling.Recent study of ionizing radiation-induced bystander effects[J].International Journal of Radiation Medicine and Nuclear Medicine,2007,31(5):303.

备注/Memo

备注/Memo:
基金项目:中国辐射防护研究院院青年基金项目(yQ130202)
通信作者:李幼忱(email:liyc69@163.com)
更新日期/Last Update: 2015-09-15