[1]贺小红,周新韩,高明勇,等.模型模拟修改部分扫描参数加速MR扫描的方法可行性探讨[J].国际放射医学核医学杂志,2016,40(4):267-271,276.[doi:10.3760/cma.j.issn.1673-4114.2016.04.006]
 He Xiaohong,Zhou Xinhan,Gao Mingyong,et al.Feasibility of accelerating MR scan by modifying part of scanning parameters:a phantom simulation study[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):267-271,276.[doi:10.3760/cma.j.issn.1673-4114.2016.04.006]
点击复制

模型模拟修改部分扫描参数加速MR扫描的方法可行性探讨(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
40
期数:
2016年第4期
页码:
267-271,276
栏目:
出版日期:
2016-07-25

文章信息/Info

Title:
Feasibility of accelerating MR scan by modifying part of scanning parameters:a phantom simulation study
作者:
贺小红 周新韩 高明勇 杨镜全 马锦城
528000, 广东省佛山市第一人民医院医学影像科MR室
Author(s):
He Xiaohong Zhou Xinhan Gao Mingyong Yang Jingquan Ma Jincheng
Department of MRI, Medical Imaging, the First People’s Hospital of Foshan, Foshan 528000, China
关键词:
磁共振成像质量控制信噪比非均匀性扫描参数
Keywords:
Magnetic resonance imagingQuality controlSignal-to-noise ratioNon-uniformityScan parameter
DOI:
10.3760/cma.j.issn.1673-4114.2016.04.006
摘要:
目的 探讨修改部分扫描参数加速MR扫描的方法。方法 先以仪器制造商提供的颈部软组织横轴位(Tra)自旋回波(SE)平扫T1加权、T2加权序列扫描Philips Achieva 1.5T MRI系统的质量控制模型;然后在数据采集界面的“Geometry、Contrast”等选项中修改视野(FOV)/矩阵(Matrix)/体素(Voxel)、并行采集(SENSE)、最小重复时间(Min.TR)、回波时间(TE)、快速自旋回波因子(TSE factor)等参数,并分别对模型相同区域进行扫描;比较参数修改前、后相应序列的总扫描时间(TSD)、图像视觉效果,并以Tra图像ROI内信噪比(SNR)、非均匀性(NU)和X轴方向profile曲线评价图像质量;采用SPSS17.0软件对相应序列定量数据进行配对t检验分析。结果 参数修改后T1加权、T2加权序列的TSD比修改前分别减少了38.5 s(25.56%)和40.0 s(22.22%).目测相应序列均匀区、线性区Tra图像和profile曲线在扫描参数修改前、后没有差异。参数修改前T1加权、T2加权的SNR均值分别为77.89、79.58,修改后为83.17、81.79,较修改前均有上升,但差异无统计学意义(t=-1.891,P=0.199;t=-1.474,P=0.278);参数修改前T1加权、T2加权的NU均值分别为6.99、6.99,修改后为6.03、6.89,较修改前均有下降,但差异无统计学意义(t=0.802,P=0.507;t=0.168,P=0.882).结论 模型模拟研究显示,合理修改扫描参数可以在确保图像质量的同时加速MR扫描。
Abstract:
Objective To investigate the feasibility of accelerating MR scan by modifying the scanning parameters. Methods First, the spine cho(SE) T1-weighted and T2-weighted sequences of neck soft tissue were used to scan the transverse(Tra) slices of the special quality control phantom of the Philips Achieva 1.5T system. The FOV/Matrix/Voxel, SENSE, Min.TR, TE, and TSE factor were modified in the “Geometry, Contrast” mode of the data acquisition interface to accelerate the scanning speed. The phantom was scanned at the same time the scanning parameters were modified. Finally, the total scan duration(TSD) of the corresponding sequences was compared. The signal-to-noise ratio(SNR), non-uniformity(NU) in the ROI, and profile curve in the X-direction of the Tra images were used to evaluate image quality before and after the scanning parameters were modified. Paired t-test was used to analyze the quantitative data. Results Approximately 38.5 s(25.56%) and 40.0 s(22.22%)were saved corresponded to the T1-weighted and T2-weighted sequences, respectively, after the scanning parameters were modified. Visual differences in the images and profile curves of the corresponding sequences were not found between before and after the modification of scanning parameters. The mean SNRs of the T1-weighted and T2-weighted sequences increased slightly after the modification, but the differences were not significant(t=-1.891, P=0.199;t=-1.474, P=0.278). The mean NUs slightly decreased after the modification, but the differences were also not significant(t=0.802, P=0.507;t=0.168, P=0.882). Conclusion The phantom test showed that the MR scan speed was accelerated and image quality was ensured by modifying the scanning parameters.

参考文献/References:

[1] 倪萍, 陈自谦.磁共振质量保证和质量控制若干问题的探讨[J].中国医疗设备, 2008, 23(6):87-89.DOI:10.3969/j.issn.1674-1633.2008.06.035.Ni P, Chen ZQ.Discussion on quality assurance and quality control of MRI[J].China Med Equip, 2008, 23(6):87-89.
[2] 康立丽, 卢广文, 余晓锷, 等.MRI扫描参数与信噪比关系的实验研究[J].中华放射学杂志, 2003, 37(3):225-227.DOI:10.3760/j.issn:1005-1201.2003.03.007.Kang LL, Lu GW, Yu XE, et al.Experimental research of the relationship between signal-to-noise ratio and scan parameters of MRI[J].Chin J Radiol, 2003, 37(3):225-227.
[3] Price RR, Axel L, Morgan T, et al.Quality assurance methods and phantoms for magnetic resonance imaging:report of AAPM nuclear magnetic resonance Task Group No.1[J].Med Phys, 1990, 17(2):287-295.
[4] National Electrical Manufacturers Association.MS 3-2008(R2014).American National Standard for Determination of Image Uniformity in Diagnostic Magnetic Resonance Images[S].Rosslyn:NEMA, 2008.
[5] Santarelli X, Garbin G, Ukmar M, et al.Dependence of the fractional anisotropy in cervical spine from the number of diffusion gradients, repeated acquisition and voxel size[J].Magn Reson Imaging, 2010, 28(1):70-76.DOI:10.1016/j.mri.2009.05.046.
[6] Kim SJ, Choi CG, Kim JK, et al.Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging:evaluation using a diffusional anisotropic phantom[J].Korean J Radiol, 2015, 16(2):297-303.DOI:10.3348/kjr.2015.16.2.297.
[7] 杨镜全, 高明勇, 罗素玲, 等.吞咽过程动态MRI的可行性探讨[J].国际放射医学核医学杂志, 2012, 36(1):52-55.DOI:10.3760/cma.j.issn.1673-4114.2012.01.013.Yang JQ, Gao MY, Luo SL, et al.The feasibility of magnetic resonance imaging of the dynamic swallowing[J].Int J Rad Med Nucl Med, 2012, 36(1):52-55.
[8] 陈武凡, 康立丽.MRI原理与技术[M].北京:科学出版社, 2012:96-97.Chen WF, Kang LL.Magnetic resonance imaging principle and technology[M].Beijing:Science Press, 2012:96-97.

相似文献/References:

[1]张奇洲,李毓斌,李肖红,等.11C-乙酸盐的自动化合成影响因素的考察及质量控制[J].国际放射医学核医学杂志,2016,40(1):6.[doi:10.3760/cma.j.issn.1673-4114.2016.01.002]
 Zhang Qizhou,Li Yubin,Li Xiaohong,et al.Study of the automated synthesis influence factors and quality control of 11C-acetate[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):6.[doi:10.3760/cma.j.issn.1673-4114.2016.01.002]
[2]岳进,苏丽萍.全身MRI与PET/CT在淋巴瘤骨髓浸润诊断及预后中的作用[J].国际放射医学核医学杂志,2016,40(1):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
 Yue Jin,Su Lipin.Function of whole-body MRI and PET/CT in the diagnosis and prognosis of lymphoma with bone marrow infiltration[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
[3]李敏,蒋涛,彭朋,等.直肠内注入模拟粪便的动态MRI对女性盆底痉挛综合征的诊断价值[J].国际放射医学核医学杂志,2016,40(3):165.[doi:10.3760/cma.j.issn.1673-4114.2016.03.001]
 Li Min,Jiang Tao,Peng Peng,et al.Value of dynamic MRI with rectum injection in the diagnosis of female spastic pelvic floor syndrome[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):165.[doi:10.3760/cma.j.issn.1673-4114.2016.03.001]
[4]唐令胜,刘朝晖,李红梅,等.低场磁共振DWI技术与常规MRI扫描对超急性脑梗死的诊断灵敏度的比较[J].国际放射医学核医学杂志,2016,40(3):187.[doi:10.3760/cma.j.issn.1673-4114.2016.03.006]
 Tang Lingsheng,Liu Zhaohui,Li Hongmei,et al.Comparison of the diagnostic sensitivity of low-field magnetic resonance diffusion weighted imaging technology and conventional MRI scanning for super acute cerebral infarction[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):187.[doi:10.3760/cma.j.issn.1673-4114.2016.03.006]
[5]卢顺琦,吴锦海,刘海宽,等.上海市数字化乳腺x射线摄影装置质量控制检测分析[J].国际放射医学核医学杂志,2015,39(5):381.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 006]
 lu shunqi,wu jinhai,liu haikuan,et al.Quality analysis of digital mammography facilities in shanghai[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(4):381.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 006]
[6]拓飞,张庆,张京,等.2014年度全国放射性核素γ能谱分析质量控制比对[J].国际放射医学核医学杂志,2015,39(5):401.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 011]
 tuo fei,zhang qing,zhang jing,et al.nationwide intercomparison for radionuclide analyses through γ-spectrometry method in 2014[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(4):401.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 011]
[7]卢瑞梁,贺小红,蔡华清,等.不同MRI序列检出聚丙烯酰胺水凝胶注射隆乳患者乳腺病变效能的比较研究[J].国际放射医学核医学杂志,2016,40(6):435.[doi:10.3760/cma.j.issn.1673-4114.2016.06.007]
 Lu Ruiliang,He Xiaohong,Cai Huaqing,et al.The different MRI sequences to detect breast lesions in polyacrylamide hydrogel injection for augmentation patients: a comparative study[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):435.[doi:10.3760/cma.j.issn.1673-4114.2016.06.007]
[8]廖光星,冷志欣,肖国有.前列腺癌骨转移影像诊断方法研究进展[J].国际放射医学核医学杂志,2016,40(6):464.[doi:10.3760/cma.j.issn.1673-4114.2016.06.012]
 Liao Guangxing,Leng Zhixin,Xiao Guoyou.Progress of imaging in the diagnosis of bone metastases of prostate cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):464.[doi:10.3760/cma.j.issn.1673-4114.2016.06.012]
[9]马彦云,张辉.磁共振体素内不相干运动扩散加权成像的原理及应用进展[J].国际放射医学核医学杂志,2016,40(6):469.[doi:10.3760/cma.j.issn.1673-4114.2016.06.013]
 Ma Yanyun,Zhang Hui.The basic principle and application progress of intravoxel incoherent motion imaging[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(4):469.[doi:10.3760/cma.j.issn.1673-4114.2016.06.013]
[10]周金鑫,张一帆.胰岛细胞移植监测的分子影像学进展[J].国际放射医学核医学杂志,2015,39(6):478.[doi:10.3760/cma.j.issn.1673-4114.2015.06.009]
 Zhou Jinxin,Zhang Yifan.Research progress of molecular imaging in monitoring islet transplantation[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(4):478.[doi:10.3760/cma.j.issn.1673-4114.2015.06.009]

备注/Memo

备注/Memo:
收稿日期:2016-2-18;改回日期:。
基金项目:佛山市科技创新专项(2015AG10004)
通讯作者:高明勇,Email:fs265h@126.com
更新日期/Last Update: 1900-01-01