[1]吴伟章.牙釉质电子顺磁共振剂量重建研究的若干进展[J].国际放射医学核医学杂志,2002,26(4):186-190.
 WU Wei-zhang.Progresses in dose reconstruction by tooth enamel electron paramagnetic resonance[J].International Journal of Radiation Medicine and Nuclear Medicine,2002,26(4):186-190.
点击复制

牙釉质电子顺磁共振剂量重建研究的若干进展(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
26
期数:
2002年第4期
页码:
186-190
栏目:
放射医学
出版日期:
1900-01-01

文章信息/Info

Title:
Progresses in dose reconstruction by tooth enamel electron paramagnetic resonance
作者:
吴伟章
300192 天津, 中国医学科学院中国协和医科大学放射医学研究所
Author(s):
WU Wei-zhang
Institute of Radiation Medicine, Chinese Academy of Medical Sciences Peking Union Medical College, Tianjin 300192, China
关键词:
电子顺磁共振牙釉质剂量重建拟合
Keywords:
electron paramagnetic resonanceenameldose reconstructionsimulation
分类号:
R144.1
摘要:
介绍了牙釉质电子顺磁共振回顾性剂量学的目前研究概况,着重阐述了低剂量区去除背景信号的新方法,同时也对其在体测量及紫外线影响等方面进行了讨论。
Abstract:
The present review focuses on the current developments on electron paramagnetic resonance (EPR)on ret-rospective dosimetry in tooth enamel.Details are presented on elimination of background signal in low dose region,in vivo EPR measurement in tooth enamel and UV effects are also discussed.

参考文献/References:

[1] Dieter R. From dating to biophysics-20 years of progress in applied ESR spectroscopy[J]. Appl Radiat Isot, 2000, 52:1023-1030.
[2] Ivannikov AI, Skvortsov VG, Stepanenko VF, et al. EPR tooth enamel dosimetry:optimization of the automated spectra deconvolution routine[J]. Health Phys, 2001, 81:124-137.
[3] Ostrowski K, Dziedzic-Gostawska A, Stachowich W, et al. Stable radiation-induced paramagnetic entities in tissue mineral and their use in calcified tissue research[A]. In:Pryar W (Ed), Free Radicals in Biology[M], Vol 4, Academic Press, New York, 1980. 321-344.
[4] Ivannikov AI, Tikunov DD, Skvortsov VG, et al. Elimination of the background signal in tooth enamel samples for EPR-dosimetry by means of physical-chemical treatment[J]. Appl Radiat Isot, 2001, 55:701-705.
[5] Haskell EH, Hayes RB, Kenner GH, et al. Electron paramagnetic resonance techniques and space biodosimetry[J]. Radia Res, 1997, 148:S51-S59.
[6] Fattibene P, Aragno D, Onori S, et al. Effectiveness of chemical etching for background electron paramagnetic resonance signal reduction in tooth enamel[J]. Health Phys, 1998, 75:500-505.
[7] Romanyukha AA, Ignatiev EA, Vasilenko EK, et al. Geographic variations in the EPR spectrum of tooth enamel[J]. Radiat Prot Dosim, 1999, 84:445-450.
[8] Romanyukha AA, Desrosiers MF, Regulla DF. Current issues on EPR dose reconstruction in tooth enamel[J]. Appl Radiat Isot, 2000, 52:1265-1273.
[9] Chumk V, Bailiff I, Baran N, et al. The first international intercomparison of EPR dosimetry with teeth:first results[J]. Appl Radiat Isot, 1996, 47:1281-1286.
[10] Haskell EH, Hayes RB, Kenner GH, et al. Achievable resolution and accuracy in EPR dosimetry of tooth enamel[J]. Radiat Prot Dosim, 1999, 84:525-535.
[11] Ignatiev EA, Romanyukha AA, Koshta AA, et al. Selective saturation method for EPR dosimetry with tooth enamel[J]. Appl Radiat Isot, 1996, 47:333-337.
[12] Dubovsky S, Kirillov V. Reconstruction of individual absorbed doses by tooth enamel on the base of non-linear simulation of their EPR spectra[J]. Appl Radiat Isot, 2001, 54:833-837.
[13] Egersdörfer S, Wieser A, Muller A. Tooth enamel as a detector material for retrospective EPR dosimetry[J]. Appl Radiat Isot, 1996, 47:1299-1303.
[14] Koshta AA, Wieser A, Ignatiev EA, et al. New computer procedure for routine EPR dosimetry on tooth enamel:description and verification[J]. Appl Radiat Isot, 2000, 52:1287-1290.
[15] Ivannikov AI, Skovortsov VG, Stepanenko VF, et al. Wide scale EPR retrospective dosimetry, results and problems[J]. Radiat Prot Dosim, 1997, 71:175-180.
[16] Nilsson J, Lund E, Lund A. The effects of UV-irradiation on the ESR dosimetry of tooth enamel[J]. Appl Radiat Isot, 2001, 54:131-139.
[17] Sholom SV, Haskell EH, Hayes RB, et al. Influenced crushing and additive irradiation procedures on EPR dosimetry of tooth enamel[J]. Radiat Meas, 1998, 29:101-111.
[18] Yamanaka C, Ikeya M, Hara H. ESR cavities for in vivo dosimetry of tooth enamel[J]. Appl Radiat Isot, 1993, 44:77-80.
[19] Miyake M, Liu KJ, Tadeusz M, et al. In vivo EPR dosimetry of accidental exposures to radiation:experimental results indicating the feasibility of practical use in human subjects[J]. Appl Radiat Isot, 2000, 52:1031-1038.
[20] Wieser A, Onori S, Aragno D, et al. Comparison of sample preparation and signal evaluation methods for EPR analysis of tooth enamel[J]. Appl Radiat Isot, 2000, 52:1059-1064.
[21] Seltzer SM, Romanyukha AA, Nagy V. Monte Carlo calculations of the dose distribution in teeth due to internal exposure from 90Sr:application to EPR tooth dosimetry[J]. Radiat Prot Dosim. 2001, 93:245-260.

相似文献/References:

[1]任越,张慧芳,胡波,等.电离辐射诱导小鼠骨电子顺磁共振信号检测的影响因素[J].国际放射医学核医学杂志,2015,39(5):371.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 004]
 ren yue,zhang huifang,hu bo,et al.influencing factors of detection on ionizing radiation-induced electron paramagnetic resonance signal in bones[J].International Journal of Radiation Medicine and Nuclear Medicine,2015,39(4):371.[doi:10. 3760 / cma. j. issn. 1673-4114. 2015. 05. 004]
[2]范亚光.牙釉质ESR回顾性剂量技术与剂量重建[J].国际放射医学核医学杂志,2002,26(2):90.
 FAN Ya-guang.Retrospective dosimetry technique of tooth enamel ESR and its application in dose reconstruction[J].International Journal of Radiation Medicine and Nuclear Medicine,2002,26(4):90.
[3]周莉.牙釉质EPR剂量测定方法的主要影响因素分析[J].国际放射医学核医学杂志,2004,28(3):128.
 ZHOU Li.An analysis of major effect factors in enamel EPR dosimetry[J].International Journal of Radiation Medicine and Nuclear Medicine,2004,28(4):128.

备注/Memo

备注/Memo:
收稿日期:2002-04-25。
作者简介:吴伟章(1977-),男,广东梅州人,硕士研究生,主要从事牙釉质345剂量重建技术的研究。
更新日期/Last Update: 1900-01-01