[1]王涛,王相成,王城,等.SPECT/CT定量技术新进展[J].国际放射医学核医学杂志,2018,(3):265-268.[doi:10.3760/cma.j.issn.1673-4114.2018.03.013]
 Wang Tao,Wang Xiangcheng,Wang Cheng,et al.New progress in SPECT/CT quantitative techniques[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):265-268.[doi:10.3760/cma.j.issn.1673-4114.2018.03.013]
点击复制

SPECT/CT定量技术新进展(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
期数:
2018年第3期
页码:
265-268
栏目:
综述
出版日期:
2018-05-25

文章信息/Info

Title:
New progress in SPECT/CT quantitative techniques
作者:
王涛 王相成 王城 王雪梅
010050 呼和浩特, 内蒙古医科大学附属医院核医学科
Author(s):
Wang Tao Wang Xiangcheng Wang Cheng Wang Xuemei
Department of Nuclear Medicine, Inner Mongolia Medical University Affiliated Hospital, Hohhot 010050, China
关键词:
单光子发射计算机体层摄影术定量校正
Keywords:
Single photon emission computed tomography computed tomographyQuantificationCorrection
DOI:
10.3760/cma.j.issn.1673-4114.2018.03.013
摘要:
SPECT一直被认为不能进行定量分析,但SPECT/CT、物理校正(光子衰减、散射等技术)及图像重建算法等技术的出现推动了SPECT/CT定量技术的发展,目前SPECT/CT已经可以进行类似PET的定量分析。多种技术的整合使SPECT/CT在图像采集及处理方面的性能进一步提高,使定量更加准确。笔者主要对SPECT/CT的硬件、物理校正、图像重建算法的临床应用及不足进行综述。
Abstract:
SPECT has always been considered as a technique thas unsuitableat cannot be used for quantitative analysis. The However, the appearance of such technologies, e.g., as SPECT/CT, physical correction (such as photon attenuation and scattering), and image reconstruction algorithms, haves promoted the development of SPECT/CT quantitative technology development. The direct integration of multiple technologies allows the further improvement of SPECT/CT to further improve performance in image acquisition and processing, thereby ensuring more accurate quantification. The authors mainly summarized the SPECT/CT hardware, physical correction, image reconstruction algorithm, and clinical application and insufficiency.

参考文献/References:

[1] Slomka PJ, Pan T, Berman DS, et al. Advances in SPECT and PET Hardware[J]. Prog Cardiovasc Dis, 2015, 57(6):566-578. DOI:10.1016/j.pcad.2015.02.002.
[2] Hsu B, Chen FC, Wu TC, et al. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease[J]. Eur J Nucl Med Mol Imaging, 2014, 41(12):2294-2306. DOI:10.1007/s00259-014-2881-9.
[3] 靳潇潇, 武志芳, 胡光, 等. IQ·SPECT、碲锌镉探测器SPECT和传统SPECT在心肌灌注显像中的应用分析[J]. 国际放射医学核医学杂志, 2017, 41(2):150-155. DOI:10.3760/cma.j.issn.1673-4114. 2017.02.013. Jin XX, Wu ZF, Hu G, et al. IQ·SPECT, Cadmium-Zinc-Telluride SPECT, and conventional SPECT application in myocardial perfusion imaging[J]. Int J Radiat Med Nucl Med, 2017, 41(2):150-155.
[4] 张宗耀, 吴大勇, 郭风, 等. 应用新型半导体SPECT检测心力衰竭患者左室容积和射血分数:与常规SPECT和心脏磁共振成像对比[J]. 中华核医学与分子影像杂志, 2017, 37(5):269-273. DOI:10.3760/cma.j.issn.2095-2848.2017.05.004. Zhang ZY, Wu DY, Guo F, et al. Myocardial perfusion imaging evaluation of left ventricular volume and ejection fraction using a novel semi-conductor SPECT:comparison to conventional SPECT and cardiac MRI[J]. Chin J Nucl Med Mol Imaging, 2017, 37(5):269-273.
[5] Bailey DL, Willowson KP. An evidence-based review of quantitative SPECT imaging and potential clinical applications[J]. J Nucl Med, 2013, 54(1):83-89. DOI:10.2967/jnumed.112.111476.
[6] Kroiss AS, Nekolla SG, Dobrozemsky G, et al. CT-based SPECT attenuation correction and assessment of infarct size:results from a cardiac phantom study[J]. Ann Nucl Med, 2017, 31(10):764-772. DOI:10.1007/s12149-017-1211-2.
[7] Meikle SR, Hutton BF, Bailey DL. A transmission-dependent method for scatter correction in SPECT[J]. J Nucl Med, 1994, 35(2):360-367.
[8] Knoll P, Rahmim A, Gültekin S, et al. Improved scatter correction with factor analysis for planar and SPECT imaging[J/OL]. Rev Sci Instrum, 2017, 88(9):094303[2017-11-15]. https://aip.scitation.org/doi/pdf/10.1063/1.5001024. DOI:10.1063/1.5001024.
[9] Holen RV, Vandenberghe S, Staelens S, et al. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators[J]. Phys Med Biol, 2009, 54(3):715-729. DOI:10.1088/0031-9155/54/3/016.
[10] EI Fakhri G, Buvat I, Benali H, et al. Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT[J]. J Nucl Med, 2000, 41(8):1400-1408.
[11] Shcherbinin S, Celler A. An investigation of accuracy of iterative reconstructions in quantitative SPECT[J/OL]. J Phys:Conf Ser,2008, 124(1):012044[2017-11-15]. http://iopscience.iop.org/article/10.1088/1742-6596/124/1/012044/pdf. DOI:10.1088/1742-6596/124/1/012044.
[12] Brambilla M, Lecchi M, Matheoud R, et al. Comparative analysis of iterative reconstruction algorithms with resolution recovery and new solid state cameras dedicated to myocardial perfusion imaging[J]. Phys Med, 2017, 41:109-116. DOI:10.1016/j.ejmp.2017.03.008.
[13] Einstein AJ, Blankstein R, Andrews H, et al. Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study[J]. J Nucl Med, 2014, 55(9):1430-1437. DOI:10.2967/jnumed.114. 138222.
[14] Parker JA, Yester MV, Daube-Witherspoon E, et al. Procedure guideline for general imaging:1.0. Society of Nuclear Medicine[J]. J Nucl Med, 1996, 37(12):2087-2092.
[15] Hesse B, Tägil K, Cuocolo A, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology[J]. Eur J Nucl Med Mol Imaging, 2005, 32(7):855-897. DOI:10.1007/s00259-005-1779-y.
[16] Gedik GK, Sari O. Influence of single photon emission computed tomography (SPECT) reconstruction algorithm on diagnostic accuracy of parathyroid scintigraphy:Comparison of iterative reconstruction with filtered backprojection[J]. Indian J Med Res, 2017, 145(4):479-487. DOI:10.4103/ijmr.IJMR_305_15.
[17] Gnesin S, Leite FP, Malterre J, et al. Phantom validation of Tc-99m absolute quantification in a SPECT/CT commercial device[J/OL]. Comput Math Methods Med, 2016, 2016:4360371[2017-11-15]. https://www.ncbi.nlm.nih.gov/pubmed/28096891. DOI:10.1155/2016/4360371.
[18] Zeraatkar N, Rahmim A, Sarkar S, et al. Development and evaluation of image reconstruction algorithms for a novel desktop SPECT system[J]. Asia Ocean J Nucl Med Biol, 2017, 5(2):120-133. DOI:10.22038/aojnmb.2017.8708.
[19] Ptácek J, Henzlová L, Koranda P. Bone SPECT image reconstruction using deconvolution and wavelet transformation: development, performance assessment and comparison in phantom and patient study with standard OSEM and resolution recovery algorithm[J]. Phys Med, 2014, 30(7):858-864. DOI:10.1016/j.ejmp.2014.06.002.
[20] Grootjans W, Meeuwis AP, Slump CH, et al. Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions[J]. Z Med Phys, 2016, 26(4):311-322. DOI:10.1016/j.zemedi.2015.12.004.
[21] Ito Y, Katoh C, Noriyasu K, et al. Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging:comparison with the results of[15O] H2O PET[J]. Eur J Nucl Med Mol Imaging, 2003,30(2):281-287. DOI:10.1007/s00259-002-1031-y.
[22] Iida H, Yokoyama I, Agostini D, et al. Quantitative assessment of regional myocardial blood flow using oxygen-15-labelled water and positron emission tomography:a multicentre evaluation in Japan[J]. Eur J Nucl Med Mol Imaging, 2000, 27(2):192-201. DOI:10.1007/s002590050026.
[23] Ben Bouallègue F, Roubille F, Lattuca B, et al. SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease:Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements[J]. J Nucl Med, 2015, 56(11):1712-1717. DOI:10.2967/jnumed.114.143164.
[24] Nakamoto R, Nakamoto Y, Ishimori T, et al. Clinical significance of quantitative 123I-MIBG SPECT/CT analysis of pheochromocytoma and paraganglioma[J/OL]. Clin Nucl Med, 2016, 41(11):e465-e472[2017-11-15]. https://insights.ovid.com/pubmed?pmid=27607159. DOI:10.1097/RLU.0000000000001334.
[25] Beck M, Sanders JC, Ritt P, et al. Longitudinal analysis of bone metabolism using SPECT/CT and 99mTc-diphosphono-propanedicarboxylic acid:comparison of visual and quantitative analysis[J]. EJNMMI Res, 2016, 6(1):60. DOI:10.1186/s13550-016-0217-4.
[26] Bailey DL, Hennessy TM, Willowson KP, et al. In vivo quantification of 177Lu with planar whole-body and SPECT/CT gamma camera imaging[J/OL]. EJNMMI Phys, 2015, 2:1-17[2017-11-15]. https://link.springer.com/content/pdf/10.1186%2Fs40658-015-0123-2.pdf. DOI:10.1186/s40658-015-0123-2.

相似文献/References:

[1]彭诗瑶,李盼丽,张艾米,等.99Tcm-MIBI SPECT/CT融合断层显像在甲状旁腺功能亢进症中的应用价值[J].国际放射医学核医学杂志,2018,(3):195.[doi:10.3760/cma.j.issn.1673-4114.2018.03.001]
 Peng Shiyao,Li Panli,Zhang Aimi,et al.Importance of 99Tcm-MIBI SPECT/CT fusion imaging in primary and secondary hyperparathyroidism[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):195.[doi:10.3760/cma.j.issn.1673-4114.2018.03.001]
[2]曹景佳,李亚明.SPECT/CT双时相联合减影技术诊断甲状旁腺功能亢进症的增益价值[J].国际放射医学核医学杂志,2018,(3):201.[doi:10.3760/cma.j.issn.1673-4114.2018.03.002]
 Cao Jingjia,Li Yaming.Incremental value of SPECT/CT fusion imaging with dual-phase and dual-tracer technique in the diagnostic localization of parathyroid lesions in patients with hyperparathyroidism[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):201.[doi:10.3760/cma.j.issn.1673-4114.2018.03.002]
[3]邓玮玮,朱娅华,范敏,等.99TcmO4-全身显像联合颈胸SPECT/CT在DTC患者术后肺转移灶显影中的应用[J].国际放射医学核医学杂志,2018,(3):207.[doi:10.3760/cma.j.issn.1673-4114.2018.03.003]
 Deng Weiwei,Zhu Yahua,Fan Min,et al.Effectiveness of 99Tcm-pertechnetate whole body scan with neck and chest SPECT/CT for the detection of post-surgical pulmonary metastasis in differentiated thyroid carcinoma patients[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):207.[doi:10.3760/cma.j.issn.1673-4114.2018.03.003]
[4]孙斌,刘举珍,张飞飞.SPECT/CT断层融合显像联合血清CEA、CYFRA21-1在诊断非小细胞肺癌骨转移中的应用[J].国际放射医学核医学杂志,2018,(3):212.[doi:10.3760/cma.j.issn.1673-4114.2018.03.004]
 Sun Bin,Liu Juzhen,Zhang Feifei.Application of SPECT/CT tomographic fusion imaging combined with serum CEA and CYFRA21-1 in the diagnosis of bone metastasis of non-small cell lung cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):212.[doi:10.3760/cma.j.issn.1673-4114.2018.03.004]
[5]刘玉珂,张敏,李培岭,等.99Tcm-MDP SPECT/CT融合骨显像评价骨折远期愈合能力的应用价值[J].国际放射医学核医学杂志,2018,(3):218.[doi:10.3760/cma.j.issn.1673-4114.2018.03.005]
 Liu Yuke,Zhang Min,Li Peiling,et al.Evaluation of fracture healing by 99Tcm-MDP SPECT/CT[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):218.[doi:10.3760/cma.j.issn.1673-4114.2018.03.005]
[6]李万婷,刘海燕,秦丽军,等.99Tcm-3PRGD2整合素受体显像鉴别乳腺良恶性病变的价值及与超声检查的对比研究[J].国际放射医学核医学杂志,2018,(3):242.[doi:10.3760/cma.j.issn.1673-4114.2018.03.009]
 Li Wanting,Liu Haiyan,Qin Lijun,et al.The evaluation of 99Tcm-3PRGD2 integrin receptor imaging in the differential diagnosis in benign and malignant breast lesions comparision with ultrasound[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):242.[doi:10.3760/cma.j.issn.1673-4114.2018.03.009]
[7]陈肖玥,张欣韵,施忠民,等.SPECT/CT骨显像在足踝关节病诊治中的应用进展[J].国际放射医学核医学杂志,2018,(5):453.[doi:10.3760/cma.j.issn.1673-4114.2018.05.012]
 Chen Xiaoyue,Zhang Xinyun,Shi Zhongming,et al.Application of SPECT/CT in diagnosis and treatment of foot and ankle diseases[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(3):453.[doi:10.3760/cma.j.issn.1673-4114.2018.05.012]

备注/Memo

备注/Memo:
收稿日期:2017-11-19。
基金项目:内蒙古自治区科技厅2016年科技计划项目(2016KJ0356);内蒙古自治区自然科学基金项目(2017MS0837)
通讯作者:王雪梅,Email:wangxuemei201010@163.com
更新日期/Last Update: 2018-05-25