Title:
Dosimetric advancement of high-dose-rate after-loading 192Ir source
作者:
张书旭1 李文华2 徐海荣2
1. 510095 广州, 广州市肿瘤医院放疗中心;
2. 510515 广州, 第一军医大学生物医学工程系
Author(s):
ZHANG Shu-xu1 LI Wen-hua2 XU Hai-rong2
1. Department of Radiation Therapy Center, Guangzhou Tumor Hospital, Guangzhou 510095, China;
2. Department of Biology Medical Engineer, First Military Medical University, Guangzhou 510515, China
关键词:
高剂量率后装治疗192Ir源三维剂量
Keywords:
high-dose-rateafter-loading brachytherapy192Ir source3-dimensional dose
分类号:
R144.1
摘要:
现代后装治疗大多采用HDR(高剂量率)微型192Ir源,其近源区剂量特性常用针点电离室、热释光剂量计测量,但ESR(电子自旋共振)胶片法测量的空间分辨率更高,可达156μm,而蒙特卡罗光子输运模拟方法是衡量测量准确度的金标准。用热释光剂量计进行直肠内剂量测量是预测直肠并发症发生率的良好指针。慢感光胶片测量192Ir源二维剂量分布精度可达1%,用基于MR(核磁共振)的凝胶剂量计测量192Ir源三维剂量分布准确度可达2.5%、空间分辨率达1.56mm,光学体层成像凝胶剂量计测量三维剂量分布具有独特的优势。
Abstract:
High-dose-rate (HDR) 192Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry.

参考文献/References:

[1] Gromoll C, Karg A. Determination of the dose characteristics in the near area of a new type of 192Ir-HDR afterloading source with a pinpoint ionization chamber[J]. Phys Med Biol,2002, 47(6):875-887.
[2] Reynaert N, Van Eijkeren M, Taeymans Y, et al. Dosimetry of 192Ir sources used for endovascular brachytherapy[J]. Phys Med Biol, 2001, 46(2):499-516.
[3] Daskalov GM, Loffler E, Williamson JF. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source[J].Med Phys, 1998, 25(11):2200-2208.
[4] Olsson S, Bergstrand ES, Carlsson AK, et al. Radiation dose measurements with alanine/agarose gel and thin alanine films around a 192Ir brachytherapy source, using ESR spectroscopy[J]. Phys Med Biol, 2002, 47(8):1333-1356.
[5] Brezovich IA, Duan J, Pareek PN, et al. In vivo urethral dose measurements:a method to verify high dose rate prostate treatments[J]. Med Phys, 2000, 27(10):2297-2301.
[6] Hood C, Duggan L, Bazley S, et al. LiF:Mg, Cu, P ’pin worms’:miniature detectors for brachytherapy dosimetry[J].Radiat Prot Dosim, 2002, 101(4):407-410.
[7] Anagnostopoulos G, Baltas D, Geretschlaeger A, et al. In vivo thermoluminescence dosimetry dose verification of transperineal 192Ir high-dose-rate brachytherapy using CTbased planning for the treatment of prostate cancer[J].Int J Radiat Oncol Biol Phys, 2003,57(4):1183-1191.
[8] Huh S J, Lim DH, Ahn YC, et al. Comparison between in vivo dosimetry and barium contrast technique for prediction of rectal complications in high-dose-rate intracavitary radiotherapy in cervix cancer patients[J]. Strahlenther Onkol,2003, 179(3):191-196.
[9] Pai S, Reinstein LE, Gluckman G, et al. The use of improved radiochromic film for in vivo quality assurance of high dose rate brachytherapy[J]. Med Phys, 1998, 25(7):1217-1221.
[10] Empesy JF, Low DA, Mutic S, et al. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imageing of acute exposure dose distributions[J].Med Phys, 2000, 27(10):2462-2475.
[11] Nutsen BH, Skretting A, Hellebust TP, et al. Determination of 3D dose distribution from intracavitary brachytherapy of cervical cancer by MRI of irradiated ferrous sulphate gel[J].Radiother Oncol, 1997, 43(2):219-227.
[12] Scherer J, Bogner L, Herbst M. The verification of optimized 3D-dosage distributions with an MR Fricke gel[J]. Strahlenther Onkol, 1997, 173(1):36-42.
[13] Calmet C, Vincensini D, Bonnet J, et al. MRI dosimetry:a fast quantitative MRI method to determine 3D absorbed dose distributions[J]. Invest Radiol, 1999, 34(3):236-241.
[14] Silva NA, Nicolucci P, Baffa O. Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom[J]. Med Phys, 2003, 30(1):17-20.
[15] Mather ML, Baldock C. Ultrasound tomography imaging of radiation dose distributions in polymer gel dosimeters:preliminary study[J]. Med Phys, 2003, 30(8):2140-2148.
[16] Kipouros P, Pappas E, Baras P, et al. Wide dynamic dose range of VIPAR polymer gel dosimetry[J]. Phys Med Biol,2001, 46(8):2143-2159.
[17] Baras P, Seimenis I, Kipouros P, et al. Polymer gel dosimetry using a three-dimensional MRI acquisition technique[J].MedPhys, 2002, 29(11):2506-2516.
[18] Oldham M, Siewerdsen JH, Shetty A, et al. High resolution gel-dosimetry by optical-CT and MR scanning[J]. Med Phys,2001, 28(7):1436-1445.
[19] Pantelisl E, Papagiannis P, Anagnostopoulos G. Evaluation of a TG-43 compliant analytical dosimetry model in clinical 192Ir HDR brachytherapy treatment planning and assessment of the significance of source position and catheter reconstruction uncertainties[J].Phus Med Biol, 2004, 49(7):55-67.
[20] Datta NR, Basu R, Das KJ, et al. Problems in reporting doses and volumes during multiple high-dose-rate intracavitary brachytherapy for carcinoma cervix as per ICRU Report 38:a comparative study using flexible and rigid applicators[J].Gynecol Oncol, 2003,91(2):285-292.

备注/Memo

备注/Memo:
收稿日期:2004-03-29。
基金项目:广东省科技计划资助项目(C30601);广东省自然科学基金资助项目(37065)
更新日期/Last Update: 1900-01-01