[1]钞卫光,张晶,陆克义.先天性肛门闭锁异位肾SPECT/CT显像一例[J].国际放射医学核医学杂志,2018,(5):472-474.[doi:10.3760/cma.j.issn.1673-4114.2018.05.016]
 Chao Weiguang,Zhang Jing,Lu Keyi.Ectopic kidney SPECT/CT imaging in a patient with congenital anal atresia[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(5):472-474.[doi:10.3760/cma.j.issn.1673-4114.2018.05.016]
点击复制

先天性肛门闭锁异位肾SPECT/CT显像一例(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
期数:
2018年第5期
页码:
472-474
栏目:
病例报告
出版日期:
2018-10-01

文章信息/Info

Title:
Ectopic kidney SPECT/CT imaging in a patient with congenital anal atresia
作者:
钞卫光 张晶 陆克义
030001 太原, 山西医科大学第一医院核医学科, 山西医科大学分子影像精准诊疗协同创新中心
Author(s):
Chao Weiguang Zhang Jing Lu Keyi
Department of Nuclear Medicine, the First Hospital of Shanxi Medical University, Molecular Imaging Precision Medicine Collaborative Innovation Center of Shanxi Medical University, Taiyuan 030001, China
DOI:
10.3760/cma.j.issn.1673-4114.2018.05.016
摘要:
笔者报道了先天性肛门闭锁异位肾SPECT/CT显像一例。异位肾患者由于早期缺乏特异性的临床症状,大多数患者都是体检时偶然发现。目前诊断异位肾主要靠超声及CT,但是对异位肾分肾肾功能的评价,肾动态显像具有明显的优势。笔者通过文献复习加深了对Gate’s法的认识,结合该病例得出指导性结论:1、对已发现有一器官畸形的新生儿,应该留意是否合并其他器官的畸形,做到早发现早干预;2、SPECT/CT可对异位肾的形态及功能进行一站式诊断,优势明显;3、对于特殊肾脏的肾小球滤过率的测定,Gate’s法需要适当的矫正。
Abstract:
SPECT/CT imaging was conducted on an ectopic kidney in a patient with congenital anal atresia. Most cases of ectopic kidney are found by chance during physical examination given the lack of the specific clinical symptoms of this condition during its early stage. At present, the diagnosis of ectopic kidneys mainly depends on ultrasound and CT. Renal dynamic imaging, however, provides advantages for the evaluation of the individual functions of ectopic kidneys. Gate’s method was used to detect the glomerular filtration rate of an ectopic kidney. Literature review was performed to obtain a deep understanding of Gate’s method. The following guiding conclusions were drawn:1. The co-occurrence of other organ malformations in newborns with kidney malformations should receive close attention. Early detection and intervention are necessary to manage ectopic kidneys. 2. SPECT/CT enables the advantageous one-stop diagnosis of the morphology and function of ectopic kidneys. 3. Gate’s method requires proper correction for the glomerular filtration rate determination of kidneys with special characteristics.

参考文献/References:

[1] Tonnesen KH, Mogensen P, Wolf H, et al. Residual kidney function after unilateral nephrectomy. Pre-and postoperative estimation by renography and clearance measurements[J]. Scand J Urol Nephrol, 1976, 10 (2):130-133. DOI:10.3109/00365597609179672.
[2] Gehan EA, George SL. Estimation of human body surface area from height and weight[J]. Cancer Chemother Rep, 1970, 54 (4):225-235.
[3] Blaufox MD, Aurell M, Bubeck B, et al. Report of the Radionuclides in Nephrourology Committee on renal clearance[J]. J Nucl Med, 1996, 37 (11):1883-1890. DOI:10.1016/S0022-5347 (01)62326-7.
[4] 杨红, 刘育青, 李聪革, 等. γ照相法GFR与双血浆标本法GFR的比较[J]. 中华核医学杂志, 2000, 20 (2):74. DOI:10.3760/cma.j.issn.0253-9780.2000.02.022. Yang H, Liu YQ, Li CG, et al. Comparison of glomerular filtration rate measurements with gamma camera methods and two plasma sample methods[J]. Chin J Nucl Med, 2000, 20 (2):74.
[5] Joung HS, Guerrero AL, Tomita S, et al. Imperforate Anus with Jejunal Atresia Complicated by Intestinal Volvulus:A Case Report[J]. J Neonatal Surg, 2016, 5 (4):59. DOI:10.21699/jns.v5i4.458.
[6] Tveter KJ, Fonkalsrud EW, Goodwin WE. Single vaginal ectopic ureter and solitary kidney, associated with imperforate anus and other malformations. A case report[J]. Scand J Urol Nephrol, 1980, 14 (1):119-121.
[7] Eckford SD, Westgate J. Solitary crossed renal ectopia associated with unicornuate uterus, imperforate anus and congenital scoliosis[J]. J Urol, 1996, 156 (1):221.
[8] Gates GF. Computation of glomerular filtration rate with Tc-99m DTPA:an in-house computer program[J]. J Nucl Med, 1984, 25 (5):613-618.
[9] 麻广宇, 邵明哲, 陈云爽, 等. 肾脏深度对SPECT测定肾小球滤过率的影响[J]. 中国医学影像技术, 2013, 29 (5):800-804. DOI:10.13929/j.1003-3289.2013.05.034. Ma GY, Shao MZ, Chen YS, et al. Impact of kidney depth on the measurement of glomerular filtration rate with SPECT[J]. Chin J Med Imaging Technol, 2013, 29 (5):800-804.
[10] 李乾, 张春丽, 王荣福. 肾动态显像测定肾小球滤过率的影响因素[J]. 中国医学影像技术, 2004, 20 (6):962-964. DOI:10.3321/j.issn:1003-3289.2004.06.046. Li Q, Zhang CL, Wang RF. Influence elements in the process of dynamic renal imaging to measure glomerular filtration rate[J]. Chin J Med Imaging Technol, 2004, 20 (6):962-964.

备注/Memo

备注/Memo:
收稿日期:2018-03-14。
通讯作者:陆克义,Email:lu-ky@163.com
更新日期/Last Update: 2018-10-01