[1]尹伟,刘日,王敏杰,等.金纳米棒作为新型CT对比剂的体外CT成像探索[J].国际放射医学核医学杂志,2018,(5):430-435.[doi:10.3760/cma.j.issn.1673-4114.2018.05.008]
 Yin Wei,Liu Ri,Wang Minjie,et al.In vitro CT imaging of gold nanorods as novel CT contrast agents[J].International Journal of Radiation Medicine and Nuclear Medicine,2018,(5):430-435.[doi:10.3760/cma.j.issn.1673-4114.2018.05.008]
点击复制

金纳米棒作为新型CT对比剂的体外CT成像探索(/HTML)
分享到:

《国际放射医学核医学杂志》[ISSN:1673-4114/CN:12-1381/R]

卷:
期数:
2018年第5期
页码:
430-435
栏目:
基础研究
出版日期:
2018-10-01

文章信息/Info

Title:
In vitro CT imaging of gold nanorods as novel CT contrast agents
作者:
尹伟 刘日 王敏杰 弓静
200433 上海, 第二军医大学附属医院长海医院影像医学科
Author(s):
Yin Wei Liu Ri Wang Minjie Gong Jing
Department of Radiology, Changhai Hospital, Second Military Medical University, Shanghai 200433, China
关键词:
纳米粒子体层摄影术X线计算机造影剂
Keywords:
Nanoparticles Tomography X-ray computed Contrast media
DOI:
10.3760/cma.j.issn.1673-4114.2018.05.008
摘要:
目的 探讨金纳米棒作为新型CT对比剂的体外CT成像参数。方法 采用金种子和生长液的方法制备金纳米棒。将聚乙二醇修饰的金纳米棒及非离子型碘对比剂(优维显370)分别制成8种浓度梯度(0、0.1、0.2、0.4、0.6、0.8、1.0、2.0 mg/mL)的溶液。将不同浓度的金纳米棒溶液在空气中及水浴中、不同管电压(80~140 kV)、不同毫安秒(50~400 mAs)等条件下进行体外CT扫描成像,观察其显影效果并测量不同浓度金纳米棒与碘对比剂的CT值。结果 ①不同浓度的金纳米棒溶液,水中扫描的CT值最接近真实值,而空气中CT值偏低;②管电压越低,金纳米棒溶液的CT值越高,当溶液浓度为2.0 mg/mL时,不同管电压下的信噪比差异均较明显;③图像质量与毫安秒呈正相关,但当毫安秒≥300 mAs时,图像质量不再有显著变化。④当扫描参数为80 kV、300 mAs时,随着浓度的增加,金纳米棒与碘对比剂的CT值也升高,并呈高度正相关关系(r=0.990、0.994,均P<0.05),但二者的CT值差异越来越大,金纳米棒较碘对比剂有更高的对比度。结论 金纳米棒具有比现有CT对比剂更优的显影特征,体外CT在80 kV、300 mAs以及水浴扫描条件下有助于获得优良的显影图像。
Abstract:
Objective To investigate the in vitro CT imaging parameters of gold nanorods as novel CT contrast agents. Methods Gold nanorods were prepared with a gold seed and a growth solution. PEG-modified gold nanorods and non-ionic iodine contrast agent were configured into eight concentrations (0, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 2.0 mg/mL). The different concentrations of the gold nanorod solutions in air and water bath were subjected to in vitro CT scanning imaging at different tube voltages (80-140 kV) and milliamp seconds (50-400 mAs). The development effect was observed, and the CT value was measured. Results (1) At different concentrations of the gold nanorod solutions, the CT value scanned in water is the closest to the true value, whereas the CT value in air is low. (2) The lower the tube voltage is, the higher the CT value of the gold nanorod solution is. At a solution concentration of 2.0 mg/mL, the difference in the signal-to-noise ratio at different tube voltages is evident. (3) The image quality is positively correlated with mAs, but the image quality is not significantly changed at ≥ 300 mAs. (3) At 80 kV and 300 mAs, the CT values of the gold nanorods and the iodine contrast agent increase as the concentration increases and show a highly positive correlation (r=0.990, 0.994, both P<0.05). The difference in CT values between the two agents increases, and the contrast of the gold nanorods is higher than that of the iodine contrast agents. Conclusion Gold nanorods exhibit superior imaging characteristics to those of existing CT contrast agents. When gold nanorods are scanned with iCT at 80 kV and 300 mAs and under water bath conditions, an excellent image quality can be achieved.

参考文献/References:

[1] 郭妍妍, 刘雅娟, 王琳, 等. 功能化高分子脂质体包裹的纳米金颗粒作为新型CT造影剂的初步研究[J]. 中国生化药物杂志, 2017, 37 (4):5-8. DOI:10.3969/j.issn.1005-1678.2017.04.002. Guo YY, Liu YJ, Wang L, et al. Preliminary research on functional polymer liposome-entrapped gold nanoparticles as CT contrast agents[J]. Chin J Biological Pharms, 2017, 37 (4):5-8.
[2] Rajkumar S, Prabaharan M. Theranostics Based on Iron Oxide and Gold Nanoparticles for Imaging-Guided Photothermal and Photodynamic Therapy of Cancer[J]. Curr Top Med Chem, 2017, 17 (16):1858-1871. DOI:10.2174/1568026617666161122120537
[3] Liu Y, Ai K, Lu L. Nanoparticulate X-ray computed tomography contrast agents:from design validation to in vivo applications[J]. Acc Chem Res, 2012, 45 (10):1817-1827. DOI:10.1021/ar300150c.
[4] Lin W, Zhang X, Qian L, et al. Doxorubicin-Loaded Unimolecular Micelle-Stabilized Gold Nanoparticles as a Theranostic Nanoplatform for Tumor-Targeted Chemotherapy and Computed Tomography Imaging[J]. Biomacromolecules, 2017, 18 (12):3869-3880. DOI:10.1021/acs.biomac.7b00810.
[5] Sasidharan S, Bahadur D, Srivastava R. Albumin stabilized gold nanostars:A biocompatible nanoplatform for SERS, CT imaging and photothermal therapy of cancer[J]. Rsc Advances, 2016, 6 (87):84025-84034. DOI:10.1039/C6RA11405A.
[6] 翟宏菊, 戴晓威, 曹爽, 等. 金纳米粒子的合成、性质及其应用新进展[J]. 吉林师范大学学报 (自然科学版), 2017, 38 (2):13-16. DOI:10.16862/j.cnki.issn1674-3873.2017.02.003. Zhai HJ, Dai XW, Cao S. New Progress of Synthesis, Properties and Applications of Gold Nanoparticles[J]. J Jilin Normal Univ (Natural Science Edition), 2017, 38 (2):13-16.
[7] 余建明. 实用医学影像技术[M]. 人民卫生出版社, 2015:501. Yu JM. Practical medical imaging technology[M]. People’s health press, 2015:501.
[8] Beik J, Jafariyan M, Montazerabadi A, et al. The benefits of folic acid-modified gold nanoparticles in CT-based molecular imaging:radiation dose reduction and image contrast enhancement[J/OL]. Artif Cells Nanomed Biotechnol, 2017:1-9[2018-01-05]. https://www.ncbi.nlm.nih.gov/pubmed/29233015. DOI:10.1080/21691401. 2017. 1408019.
[9] Seibert JA, Boone JM. X-ray imaging physics for nuclear medicine technologists. Part 2:X-ray interactions and image formatio[J]. J Nucl Med Technol, 2005, 33 (1):3-18.
[10] Kang S, Eom J, Kim B, et al. Evaluation of gold K-edge imaging using spectral computed tomography with a photon-counting detector:A Monte Carlo simulation study[J]. Optik-Inter J Light Electron Optics, 2017, 140:253-260. DOI:10.1016/j.ijleo.2017.04. 062.
[11] 李锋坦, 李东, 张云亭. 管电压对CT值测量、辐射剂量及图像质量影响的模型研究[J]. 中华放射学杂志, 2013, 47 (5):458-461. DOI:10.3760/cma.j.issn.1005-1201.2013.05.016. Li FT, Li D, Zhang YT. Influence of tube voltage on CT attenuation, radiation dose, and image quality:phantom study[J]. Chin J Radiol, 2013, 47 (5):458-461.

相似文献/References:

[1]周玉祥,蓝博文,黄春榆,等.64排螺旋CT冠状动脉血管成像诊断冠状动脉-肺动脉瘘的应用价值[J].国际放射医学核医学杂志,2016,40(1):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
 Zhou Yuxiang,Lan Bowen,Huang Chunyu,et al.Clinical value of coronary artery-pulmonary artery fistula revealed by 64-slice spiral CT coronary angiography[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):26.[doi:10.3760/cma.j.issn.1673-4114.2016.01.006]
[2]陈超坤,刘亮,傅飞先,等.囊性胸腺瘤和囊性畸胎瘤的影像学特征及鉴别诊断[J].国际放射医学核医学杂志,2016,40(1):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
 Chen Chaokun,Liu Liang,Fu Feixian,et al.Imaging features and differential diagnosis of cystic thymoma and cystic teratoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):31.[doi:10.3760/cma.j.issn.1673-4114.2016.01.007]
[3]岳进,苏丽萍.全身MRI与PET/CT在淋巴瘤骨髓浸润诊断及预后中的作用[J].国际放射医学核医学杂志,2016,40(1):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
 Yue Jin,Su Lipin.Function of whole-body MRI and PET/CT in the diagnosis and prognosis of lymphoma with bone marrow infiltration[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):50.[doi:10.3760/cma.j.issn.1673-4114.2016.01.010]
[4]张莹莹,王振光,孔艳.PET/CT显像在肺间质纤维化中的应用进展[J].国际放射医学核医学杂志,2016,40(1):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
 Zhang Yingying,Wang Zhenguang,Kong Yan.Application advancement on PET/CT in pulmonary interstitial fibrosis[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):55.[doi:10.3760/cma.j.issn.1673-4114.2016.01.011]
[5]麦卫平,张永林.能谱CT成像在肺癌诊断中的应用研究进展[J].国际放射医学核医学杂志,2016,40(1):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
 Mai Weiping,Zhang Yonglin.Research progress of spectral imaging in the diagnosis of lung cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):77.[doi:10.3760/cma.j.issn.1673-4114.2016.01.015]
[6]史文杰,孟召伟,谭建.基于Deauville标准探讨18F-FDG PET/CT在霍奇金淋巴瘤复发诊断中的应用价值[J].国际放射医学核医学杂志,2016,40(2):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
 Shi Wenjie,Meng Zhaowei,Tan Jian.Value of 18F-FDG PET/CT on diagnosis of Hodgkin lymphoma recurrence using Deauville criterion[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):120.[doi:10.3760/cma.j.issn.1673-4114.2016.02.007]
[7]周翠屏,廖俊杰,何国华,等.原发性肠系膜巨大淋巴结增生症的MSCT表现与病理对照分析[J].国际放射医学核医学杂志,2016,40(3):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
 Zhou Cuiping,Liao Junjie,He Guohua,et al.Primary mesenteric Castleman disease:MSCT findings with histopathologic correlation[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):175.[doi:10.3760/cma.j.issn.1673-4114.2016.03.003]
[8]张巧娜,刘汉东.上颌窦上皮-肌上皮癌的CT表现一例[J].国际放射医学核医学杂志,2016,40(3):237.[doi:10.3760/cma.j.issn.1673-4114.2016.03.015]
[9]尤阳,轩昂,张杰,等.淋巴瘤患者大脑静息葡萄糖代谢改变[J].国际放射医学核医学杂志,2016,40(4):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
 You Yang,Xuan Ang,Zhang Jie,et al.Changes in resting-state brain glucose metabolism in patients with lymphoma[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):255.[doi:10.3760/cma.j.issn.1673-4114.2016.04.003]
[10]王朋,崔邦平,代文莉,等.18F-FDG PET/CT在前列腺癌中的应用进展[J].国际放射医学核医学杂志,2016,40(4):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]
 Wang Peng,Cui Bangping,Dai Wenli,et al.Progress in the application of 18F-FDG PET/CT in prostate cancer[J].International Journal of Radiation Medicine and Nuclear Medicine,2016,40(5):277.[doi:10.3760/cma.j.issn.1673-4114.2016.04.008]

备注/Memo

备注/Memo:
收稿日期:2018-01-07。
基金项目:国家自然科学基金(81400368)
通讯作者:弓静,Email:gong.jing1980@163.com
更新日期/Last Update: 2018-10-01